Epson GS6000 Error CodesMaintenance Request Errors
MAINTENANCE REQUEST - 0001 - The CR scan pass counter has reached the specified value. MAINTENANCE REQUEST - 0011 - The RTC backup battery becomes exhausted.
MAINTENANCE REQUEST - 0111 - The date has not been set.
MAINTENANCE REQUEST - 0100 - The following two errors are occurring simultaneously, 0001 & 0011
MAINTENANCE REQUEST - 1000 - The following two errors are occurring simultaneously, 0001 & 0011
MAINTENANCE REQUEST - 1010 - The following two errors are occurring simultaneously, 0011 & 0111
Service Call Errors
SERVICE CALL ERROR - 1101 - Life end of the CR MOTOR
SERVICE CALL ERROR - 1125 - Carriage home position detection
SERVICE CALL ERROR - 1133 - CR MOTOR in position time-out error
SERVICE CALL ERROR - 1135 - CR ENC ASSY check error
SERVICE CALL ERROR - 1136 - CR MOTOR step-out error
SERVICE CALL ERROR - 1137 - CR servo parameter error
SERVICE CALL ERROR - 1223 - PF ENCODER ASSY check error
SERVICE CALL ERROR - 1225 - PF MOTOR in position time-out error
SERVICE CALL ERROR - 1227 - PF MOTOR step-out error
SERVICE CALL ERROR - 1228 - PF servo parameter error
SERVICE CALL ERROR - 131B - Head driver (transmission gate) overheat error
SERVICE CALL ERROR - 1700 - Print position error
SERVICE CALL ERROR - 1900 - HEATER CONT BOARD ASSY serial connection failure
SERVICE CALL ERROR - 1902 - Over Temp PRE HEATERS(64) on the HEATER RELAY BOARD ASSY
SERVICE CALL ERROR - 1903 - Over Temp PLATEN HEATER(64) on the HEATER RELAY BOARD ASSY
SERVICE CALL ERROR - 1904 - Over Temp AFTER HEATER(64) on the HEATER RELAY BOARD ASSY
SERVICE CALL ERROR - 1905 - Over Temp PRE HEATERS(64) on the HEATER RELAY BOARD ASSY
SERVICE CALL ERROR - 1906 - Over Temp PLATEN HEATER(64) on the HEATER RELAY BOARD ASSY
SERVICE CALL ERROR - 1907 - Over Temp AFTER HEATER(64) on the HEATER RELAY BOARD ASSY
SERVICE CALL ERROR - 1908 - An abnormal voltage of the heater on the HEATER CONT BOARD ASSY
SERVICE CALL ERROR - 1909 - Comms Failure HEATER CONT BOARD ASSY and SUB-B/C BOARD
SERVICE CALL ERROR - 1910 - Under Temp PRE HEATERS(64) on the HEATER RELAY BOARD ASSY
SERVICE CALL ERROR - 1911 - Under Temp PLATEN HEATER on the HEATER RELAY BOARD ASSY
SERVICE CALL ERROR - 1912 - Under Temp AFTER HEATER on the HEATER RELAY BOARD ASSY
SERVICE CALL ERROR - 1920 - HEATER CONT BOARD ASSY-SUB TANK SENSOR 1 failure
SERVICE CALL ERROR - 1921 - HEATER CONT BOARD ASSY-SUB TANK SENSOR 2 failure
SERVICE CALL ERROR - 1922 - HEATER CONT BOARD ASSY-SUB TANK SENSOR 3 failure
SERVICE CALL ERROR - 1923 - HEATER CONT BOARD ASSY-SUB TANK SENSOR 4 failure
SERVICE CALL ERROR - 1924 - HEATER CONT BOARD ASSY-SUB TANK SENSOR 5 failure
SERVICE CALL ERROR - 1925 - HEATER CONT BOARD ASSY-SUB TANK SENSOR 6 failure
SERVICE CALL ERROR - 1926 - HEATER CONT BOARD ASSY-SUB TANK SENSOR 7 failure
SERVICE CALL ERROR - 1927 - HEATER CONT BOARD ASSY-SUB TANK SENSOR 8 failure
SERVICE CALL ERROR - 1A23 - RTC analysis error
SERVICE CALL ERROR - 1A26 - RTC communication error
SERVICE CALL ERROR - 1A37 - Head thermistor error
SERVICE CALL ERROR - 1A38 - Transistor thermistor error
SERVICE CALL ERROR - 1A39 - Head error
SERVICE CALL ERROR - 1A40 - MAIN BOARD ASSY IC2 error
SERVICE CALL ERROR - 1A41 - Head rank ID input error
SERVICE CALL ERROR - 2000 - NVRAM error
SERVICE CALL ERROR - 2002 - SDRAM error
SERVICE CALL ERROR - 2003 - Boot program sum error
SERVICE CALL ERROR - 200A - Program loading error
SERVICE CALL ERROR - 200B - Internal insufficient memory error
SERVICE CALL ERROR - 200C - Servo interrupt watchdog time-out error
SERVICE CALL ERROR - 200D - System interrupt watchdog timeout error
SERVICE CALL ERROR - 200E - Unknown NMI
SERVICE CALL ERROR - 3000 - AC power shut-off
SERVICE CALL ERROR - FXXX - CPU-related error
Epson 11880 Error Codes
Maintenance Request Errors
MAINTENANCE REQ - 0001 - The counter of waste ink at borderless printing has reached the specified value.
MAINTENANCE REQ - 0002 - The CR scan pass counter has reached the specified value.
MAINTENANCE REQ - 0008 - The RTC backup battery becomes exhausted.
MAINTENANCE REQ - 0040 - The pump counter has reached the specified value.
MAINTENANCE REQ - 0080 - The date has not been set.
MAINTENANCE REQ - 0100 - The RTC backup battery power has temporarily dropped.
MAINTENANCE REQ - 0088 - The RTC backup battery becomes exhausted and the date has not been set
Service Request Errors
SERVICE REQ - 1101 - Life end of the Ink Tube
SERVICE REQ - 1125 - Carriage home position detection error
SERVICE REQ - 1133 - The CR Motor in position time-out error
SERVICE REQ - 1135 - CR Encoder check error
SERVICE REQ - 1136 - CR Motor Step-out error
SERVICE REQ - 1137 - CR servo parameter error
SERVICE REQ - 1223 - PF Encoder check error
SERVICE REQ - 1225 - The PF Motor in position time-out error
SERVICE REQ - 1227 - PF Motor Step-out error
SERVICE REQ - 1228 - PF servo parameter error
SERVICE REQ - 1400 - Pressure failure error
SERVICE REQ - 1410 - Pump motor drive timeover error
SERVICE REQ - 1430 - Cartridge Holder Maintenance
SERVICE REQ - 1434 - Ink cover unlock error
SERVICE REQ - 1435 - Cap hp detection error
SERVICE REQ - 1436 - Select valve hp detection error
SERVICE REQ - 1437 - Cap motor drive timeover error
SERVICE REQ - 1441 - Pressure motor 1 acceleration error
SERVICE REQ - 1442 - Pressure motor 2 acceleration error
SERVICE REQ - 1443 - Pressure motor 3 acceleration error
SERVICE REQ - 1461 - Pressure motor 1 lock error
SERVICE REQ - 1462 - Pressure motor 2 lock error
SERVICE REQ - 1463 - Pressure motor 3 lock error
SERVICE REQ - 1471 - Pessure motor 1 reverse detection error
SERVICE REQ - 1472 - Pressure motor 2 reverse detection error
SERVICE REQ - 1473 - Pressure motor 3 reverse detection error
SERVICE REQ - 1511 - APG motor drive timeover error
SERVICE REQ - 1536 - Pressurizing reset failure
SERVICE REQ - 1700 - Print position error
SERVICE REQ - 1800 - AID voltage error
SERVICE REQ - 2000 - NVRAM error
SERVICE REQ - 2002 - SDRAM error
SERVICE REQ - 2003 - BOOT program sum error
SERVICE REQ - 3000 - AC power shut-off
SERVICE REQ - 131B - Head driver (transmission gate) overheat error
SERVICE REQ - 150C - PG hp detection error
SERVICE REQ - 16A0 - Cap unit status error 1
SERVICE REQ - 16A1 - Cap unit status error 2
SERVICE REQ - 16B0 - Cap hp detection retry error
SERVICE REQ - 1A23 - RTC analysis error
SERVICE REQ - 1A26 - RTC communication error
SERVICE REQ - 1A37 - Head thermistor error
SERVICE REQ - 1A38 - Transistor thermistor error
SERVICE REQ - 1A39 - Head error
SERVICE REQ - 1A40 - Main board IC2 error
SERVICE REQ - 1A41 - Head rank ID input error
SERVICE REQ - 200A - Program loading error
SERVICE REQ - 200B - Internal insufficient memory error
SERVICE REQ - 200C - Servo interrupt watchdog time-out error
SERVICE REQ - 200D - System interrupt watchdog time-out error
SERVICE REQ - 200E - Unknown NMI
SERVICE REQ - DXXX - Debug error
SERVICE REQ - FXXX - CPU-related error
SERVICE REQ - F000 - CPU-related error
Epson 7700 9900 Error Codes
Maintenance Request Errors
MAINTENANCE REQ - 0002 - The CR scan pass counter has come near the specified life.
MAINTENANCE REQ - 0008 - The RTC backup battery becomes exhausted
MAINTENANCE REQ - 0010 - Communication with the AID Board is not established.
MAINTENANCE REQ - 0040 - The pump counter has come near the specified life.
MAINTENANCE REQ - 0080 - The date has not been set
MAINTENANCE REQ - 0800 - Cartridge waste ink pad near end of life
MAINTENANCE REQ - 1000 *1 - Ink Selector near end of life
MAINTENANCE REQ - 4000 - It detects twice in a row that all the nozzles are clogging.
MAINTENANCE REQ - 0088 - The RTC backup battery becomes exhausted and the date has not been set.
Service Request Errors
SERVICE REQ - 1101 - CR life error
SERVICE REQ - 1125 - CR hp detection error
SERVICE REQ - 1138 - Over current error
SERVICE REQ - 113A - Overload error
SERVICE REQ - 113B - Over speed error
SERVICE REQ - 113C - Reversing error
SERVICE REQ - 113D - Driving time-out error
SERVICE REQ - 113E - Velocity deviation error
SERVICE REQ - 113F - Lock error
SERVICE REQ - 122A - Overload error
SERVICE REQ - 122B - Over speed error
SERVICE REQ - 122C - Reversing error
SERVICE REQ - 122D - Driving time-out error
SERVICE REQ - 122E - Velocity deviation error
SERVICE REQ - 122F - Lock error
SERVICE REQ - 131B - Head driver (transmission gate) overheat error
SERVICE REQ - 13F0 - ICL operation error
SERVICE REQ - 1411 - Select error
SERVICE REQ - 1412 - Pump life error
SERVICE REQ - 1419 - Pump release error
SERVICE REQ - 141A - Overload error
SERVICE REQ - 141B - Over speed error
SERVICE REQ - 141C - Reversing error
SERVICE REQ - 141D - Driving time-out error
SERVICE REQ - 141E - Velocity deviation error
SERVICE REQ - 141F - Lock error
SERVICE REQ - 1427 - CSIC destination setting error
SERVICE REQ - 1428 - Ink holder Board Assy
SERVICE REQ - 1430 - Holder ink pad error
SERVICE REQ - 1431 - Ink selector life error
SERVICE REQ - 1434 - IC cover unlock error
SERVICE REQ - 1438 - Maintenance tank error
SERVICE REQ - 1439 - Cap error
SERVICE REQ - 143A - Overload error
SERVICE REQ - 143B - Over speed error
SERVICE REQ - 143C - Reversing error
SERVICE REQ - 143D - Driving time-out error
SERVICE REQ - 143E - Velocity deviation error
SERVICE REQ - 143F - Lock error
SERVICE REQ - 144A - Overload error
SERVICE REQ - 144B - Over speed error
SERVICE REQ - 144C - Reversing error
SERVICE REQ - 144D - Driving time-out error
SERVICE REQ - 144E - Velocity deviation error
SERVICE REQ - 144F - Lock error
SERVICE REQ - 1489 - Wiper error
SERVICE REQ - 148A - Overload error
SERVICE REQ - 148B - Over speed error
SERVICE REQ - 148C - Reversing error
SERVICE REQ - 148D - Driving time-out error
SERVICE REQ - 148E - Velocity deviation error
SERVICE REQ - 148F - Lock error
SERVICE REQ - 1494 - Ink selector error
SERVICE REQ - 1496 - Ink selector sensor error detection
SERVICE REQ - 1497 - Switching time-out error
SERVICE REQ - 149D - Driving time-out error
SERVICE REQ - 1501 - Release motor phase detection error
SERVICE REQ - 150C - PG phase detection error
SERVICE REQ - 151A - Overload error
SERVICE REQ - 151B - Over speed error
SERVICE REQ - 151C - Reversing error
SERVICE REQ - 151D - Driving time-out error
SERVICE REQ - 151E - Velocity deviation error
SERVICE REQ - 151F - Lock error
SERVICE REQ - 152A - Overload error
SERVICE REQ - 152B - Over speed error
SERVICE REQ - 152C - Reversing error
SERVICE REQ - 152D - Driving time-out error
SERVICE REQ - 152E - Velocity deviation error
SERVICE REQ - 152F - Lock error
SERVICE REQ - 1530 - Driven roller hp detection error
SERVICE REQ - 1536 - Pressurizing reset error
SERVICE REQ - 1537 - Pressurizing error
SERVICE REQ - 153A - Overload error
SERVICE REQ - 153B - Over speed error
SERVICE REQ - 153C - Reversing error
SERVICE REQ - 153D - Driving time-out error
SERVICE REQ - 153E - Velocity deviation error
SERVICE REQ - 153F - Lock error
SERVICE REQ - 1540 - Cutter hp detection error
SERVICE REQ - 1541 - Cutter return error
SERVICE REQ - 1549 - Motor disconnection error
SERVICE REQ - 154A - Overload error
SERVICE REQ - 154B - Over speed error
SERVICE REQ - 154C - Reversing error
SERVICE REQ - 154D - Driving time-out error
SERVICE REQ - 154E - Velocity deviation error
SERVICE REQ - 154F - Lock error
SERVICE REQ - 1551 - Paper thickness determining error
SERVICE REQ - 1561 - Paper thickness at power-on error
SERVICE REQ - 1800 - AID voltage error
SERVICE REQ - 1A23 - Incorrect RTC data error
SERVICE REQ - 1A26 - RTC Access T/O error
SERVICE REQ - 1A37 - Thermistor error
SERVICE REQ - 1A38 - Transistor environmental temperature error
SERVICE REQ - 1A39 - Head error
SERVICE REQ - 1A40 - IC22 error
SERVICE REQ - 1A41 - Head rank ID input error
SERVICE REQ - 1A50 - I2C communication error (Between elements on ASIC and MAIN)
SERVICE REQ - 1A51 - I2C communication error (Between elements on SUB and MAIN)
SERVICE REQ - 1A52 I- 2C communication error (Between elements on SUB-B and MAIN)
SERVICE REQ - 1A53 - I2C communication error (Between elements on SUB-C and MAIN)
SERVICE REQ - 2000 - NVRAM error
SERVICE REQ - 2002 - SDRAM error
SERVICE REQ - 2003 - FLASH BOOT SUM CHECK error
SERVICE REQ - 200A - F/W load error
SERVICE REQ - 200D - System interrupt watchdog time-out error
SERVICE REQ - 200E - Unknown NMI
SERVICE REQ - 2010 - UART communication error
SERVICE REQ - 3000 - AC shut-off
SERVICE REQ - D131 - AID error
SERVICE REQ - Fxxx - CPU-related error
SERVICE REQ - Dxxx - Debug error
Spectroproofer and Auto Take-Up Error Codes
NOTE: SpectroProofer-related errors do not occur on Epson Stylus Pro 7700/7710/7700M/7710M/9700/9710 because it does not support the SpectroProofer.
Auto Take-up Reel-related errors do not occur on Epson Stylus Pro 7700/7710/7700M/7710M/7900/7910/WT7900/WT7910//7890/7908 because it does not support the Auto Take-up Reel.
Errors related to the SpectroProofer and Auto Take-up Reel do not occur on Epson Stylus Pro 7700M/7710M.
D3 - Driving auto take-up system
D6 - Driving paper pressing system
65 - Cooling Fan lock detection error
12 - Paper Pressing Plate Sensor no detection error
13 - Foreign material detection error in paper pressing
14 - Paper pressing origin position detection failure error
15 - CR hp Sensor no detection error
16 - Paper pressing system abnormal measurement value error
17 - Take-up system abnormal measurement value error
20 - Slack Sensor no detection error
01 - Mechanism is not installed -(Mount Sensor is OFF)
30 - Driving time-out error
31 - Overload error
32 - Over speed error
33 - Reversing error
34 - Velocity deviation error
35 - Lock error
40- Driving time-out error
41 - Overload error
42 - Over speed error
43 - Reversing error
44 - Velocity deviation error
45 - Lock error
20 - Driving time-out error
Epson 7600 9600 Error Codes
Maintenance Requests Errors
MAINTENANCE REQ - 0040 - Cleaning unit is nearing the end of life.
MAINTENANCE REQ - 0002 - Carriage motor is nearing the end of life.
MAINTENANCE REQ - 0008 - RTC backup battery is empty.
MAINTENANCE REQ - 0020 - The number of shots (per nozzle) reaches the limit .
MAINTENANCE REQ - 0088 - The RTC backup battery is not installed.
MAINTENANCE REQ - 0080 - Data is not specified.
MAINTENANCE REQ - 0100 - RTC backup battery is dropped instantaneously.
Service Request Errors
SERVICE REQ - 00000101 - CR motor life
SERVICE REQ - 00010000 - PF motor encoder check error
SERVICE REQ - 00010001 - PF motor out of step
SERVICE REQ - 00010002 - PF motor overcurrent
SERVICE REQ - 00010003 - PF motor in-position time-out
SERVICE REQ - 00010004 - CR motor encoder check error
SERVICE REQ - 00010005 - CR motor out of step
SERVICE REQ - 00010006 - CR motor overcurrent
SERVICE REQ - 00010007 - CR motor in-position time-out
SERVICE REQ - 00010008 - Servo interrupt watchdog time-out
SERVICE REQ - 00010009 - System interrupt watchdog time-out
SERVICE REQ - 0001000A - CR home position sensor error
SERVICE REQ - 0001000B - PF home position sensor error
SERVICE REQ - 0001000C - Head slide (PG) home position sensor error
SERVICE REQ - 0001000F - CR motor PWM output faulty
SERVICE REQ - 00010010 - PF motor PWM output faulty
SERVICE REQ - 0001001B - Head driver (TG) temperature error
SERVICE REQ - 0001001D - CR servo parameter error
SERVICE REQ - 0001001E - PF servo parameter error
SERVICE REQ - 00010020 - CSIC reed/right error
SERVICE REQ - 00010022 - Ink type error (setting on printer body side)
SERVICE REQ - 00010023 - RTC analysis error
SERVICE REQ - 00010025 - CSIC ROM communication error
SERVICE REQ - 00010026 - RTC communication error
SERVICE REQ - 00010028 - Head error
SERVICE REQ - 00010029 - Unidentified NMI
SERVICE REQ - 0001002A - CR ASIC ECU error
SERVICE REQ - 0001002B - PF ASIC ECU error
SERVICE REQ - 00020000 - NVRAM error
SERVICE REQ - 00020002 - SDRAM error
SERVICE REQ - 00020003 - BOOT program SUM error
SERVICE REQ - 00020004 - NVRAM error (3K)
SERVICE REQ - 00020005 - NVRAM error (32K)
SERVICE REQ - 00020009 - Flash memory SUM error
SERVICE REQ - 0002000A - Program load error
SERVICE REQ - 0002000B - Internal memory shortage error
SERVICE REQ - 0002000C - Review error
SERVICE REQ - 100000E0 - CPU address error (load misalignment)
SERVICE REQ - 10000100 - CPU address error (storage misalignment)
SERVICE REQ - 10000180 - CPU reserve command code exception error
SERVICE REQ - 100001A0 - CPU slot illegal command exception error
SERVICE REQ - 100005C0 - CPU DMA address error
SERVICE REQ - 10000xxx - CPU error
Epson 7xx0 9xx0 Error Codes
Maintenance Requests Errors
MAINTENANCE REQ - 0002 - The number of carriage movement cycles reached the specified value.
MAINTENANCE REQ - 0008 - The RTC backup battery run down or is not installed.
MAINTENANCE REQ - 0040 - The pump counter reached the specified upper limit.
MAINTENANCE REQ - 0080 - The date and time has not been set.
MAINTENANCE REQ - 0100 - A momentary drop in voltage of the RTC backup battery
MAINTENANCE REQ - 0400 - The Pressure Pump counter reached the specified upper limit.
Service Request Errors
SERVICE REQ - 00000101 - The CR Motor reached its end of life.
SERVICE REQ - 00010000 - PF Encoder check error
SERVICE REQ - 00010001 - The PF Motor is out of step.
SERVICE REQ - 00010002 - Overcurrent occurred on the PF Motor.
SERVICE REQ - 00010003 - The PF Motor out of position time-out error
SERVICE REQ - 00010004 - CR Encoder check error
SERVICE REQ - 00010005 - CR Motor is out of step.
SERVICE REQ - 00010007 - The CR Motor out of position time-out error
SERVICE REQ - 00010008 - Servo interrupt watchdog time-out error
SERVICE REQ - 00010009 - System interrupt watchdog time-out error
SERVICE REQ - 0001000A - Carriage home position detection error
SERVICE REQ - 0001000C - PG home position detection error
SERVICE REQ - 00010014 - Failure of pressurizing
SERVICE REQ - 0001001B - Head driver (TG) temperature error
SERVICE REQ - 0001001D - CR servo parameter error
SERVICE REQ - 0001001E - PF servo parameter error
SERVICE REQ - 00010020 - CSIC reading/writing error
SERVICE REQ - 00010023 - RTC analyzing error
SERVICE REQ - 00010026 - RTC communication error
SERVICE REQ - 00010027 - Pressure pump micro air-leak error
SERVICE REQ - 00010028 - Head error
SERVICE REQ - 0001002A - CR ASIC ECU error
SERVICE REQ - 0001002D - The Cleaning Unit reached its end of life.
SERVICE REQ - 00010035 - Pump phase detection error
SERVICE REQ - 00010036 - Type-B board installation error
SERVICE REQ - 00010037 - Head thermistor error
SERVICE REQ - 00010038 - Transistor thermistor error
SERVICE REQ - 0001003E - Pressure Sensor failure
SERVICE REQ - 0001003F - The Pressure Motor reached its end of life.
SERVICE REQ - 00010040 - Printing position error
SERVICE REQ - 00020000 - NVRAM error
SERVICE REQ - 00020002 - SDRAM error
SERVICE REQ - 00020003 - Boot program sum error
SERVICE REQ - 0002000A - Program load error
SERVICE REQ - 0002000B - The internal memory is insufficient.
SERVICE REQ - 0Dxxxxxx - An error code for debugging
SERVICE REQ - 0Exxxxxx - A time-lag of the RTC timer
SERVICE REQ - 100000E0 - CPU address error (load)
SERVICE REQ - 10000100 - CPU address error (store)
SERVICE REQ - 10000180 - CPU reserved command code exception error
SERVICE REQ - 100001A0 - CPU slot undefined command exception error
SERVICE REQ - 100001C0 - The AC power is shut off.
SERVICE REQ - 100005C0 - CPU DMA address error
SERVICE REQ - 10000xxx - CPU error
Epson 7xx0 9xx0 Error Codes
Maintenance Requests Errors
MAINTENANCE REQ - 0002 - The number of carriage movement cycles reached the specified value.
MAINTENANCE REQ - 0008 - The RTC backup battery run down or is not installed.
MAINTENANCE REQ - 0040 - The pump counter reached the specified upper limit.
MAINTENANCE REQ - 0080 - The date and time has not been set.
MAINTENANCE REQ - 0100 - A momentary drop in voltage of the RTC backup battery
MAINTENANCE REQ - 0400 - The Pressure Pump counter reached the specified upper limit.
Service Request Errors
SERVICE REQ - 00000101 - The CR Motor reached its end of life.
SERVICE REQ - 00010000 - PF Encoder check error
SERVICE REQ - 00010001 - The PF Motor is out of step.
SERVICE REQ - 00010002 - Overcurrent occurred on the PF Motor.
SERVICE REQ - 00010003 - The PF Motor out of position time-out error
SERVICE REQ - 00010004 - CR Encoder check error
SERVICE REQ - 00010005 - CR Motor is out of step.
SERVICE REQ - 00010007 - The CR Motor out of position time-out error
SERVICE REQ - 00010008 - Servo interrupt watchdog time-out error
SERVICE REQ - 00010009 - System interrupt watchdog time-out error
SERVICE REQ - 0001000A - Carriage home position detection error
SERVICE REQ - 0001000C - PG home position detection error
SERVICE REQ - 00010014 - Failure of pressurizing
SERVICE REQ - 0001001B - Head driver (TG) temperature error
SERVICE REQ - 0001001D - CR servo parameter error
SERVICE REQ - 0001001E - PF servo parameter error
SERVICE REQ - 00010020 - CSIC reading/writing error
SERVICE REQ - 00010023 - RTC analyzing error
SERVICE REQ - 00010026 - RTC communication error
SERVICE REQ - 00010027 - Pressure pump micro air-leak error
SERVICE REQ - 00010028 - Head error
SERVICE REQ - 0001002A - CR ASIC ECU error
SERVICE REQ - 0001002D - The Cleaning Unit reached its end of life.
SERVICE REQ - 00010035 - Pump phase detection error
SERVICE REQ - 00010036 - Type-B board installation error
SERVICE REQ - 00010037 - Head thermistor error
SERVICE REQ - 00010038 - Transistor thermistor error
SERVICE REQ - 0001003E - Pressure Sensor failure
SERVICE REQ - 0001003F - The Pressure Motor reached its end of life.
SERVICE REQ - 00010040 - Printing position error
SERVICE REQ - 00020000 - NVRAM error
SERVICE REQ - 00020002 - SDRAM error
SERVICE REQ - 00020003 - Boot program sum error
SERVICE REQ - 0002000A - Program load error
SERVICE REQ - 0002000B - The internal memory is insufficient.
SERVICE REQ - 0Dxxxxxx - An error code for debugging
SERVICE REQ - 0Exxxxxx - A time-lag of the RTC timer
SERVICE REQ - 100000E0 - CPU address error (load)
SERVICE REQ - 10000100 - CPU address error (store)
SERVICE REQ - 10000180 - CPU reserved command code exception error
SERVICE REQ - 100001A0 - CPU slot undefined command exception error
SERVICE REQ - 100001C0 - The AC power is shut off.
SERVICE REQ - 100005C0 - CPU DMA address error
SERVICE REQ - 10000xxx - CPU error
Epson 4900 4910 Error Codes
Maintenance Request Errors
MAINTENANCE REQ - 0002 - The CR scan pass counter has come near the specified life.
MAINTENANCE REQ - 0008 - The RTC backup battery becomes exhausted
MAINTENANCE REQ - 0010 - Communication with the AID Board is not established.
MAINTENANCE REQ - 0040 - The pump counter has come near the specified life.
MAINTENANCE REQ - 0080 - The date has not been set
MAINTENANCE REQ - 0800 - Cartridge holder diaphragm near end of life
MAINTENANCE REQ - 1000 - Ink Selector near end of life
MAINTENANCE REQ - 4000 - It detects twice in a row that all the nozzles are clogging.
MAINTENANCE REQ - 0088 - The RTC backup battery becomes exhausted and the date has not been set.
Service Request Errors
SERVICE REQ - 1101 - CR life error
SERVICE REQ - 1125 - CR hp detection error
SERVICE REQ - 1138 - Over current error
SERVICE REQ - 113A - Overload error
SERVICE REQ - 113B - Over speed error
SERVICE REQ - 113C - Reversing error
SERVICE REQ - 113D - Driving time-out error
SERVICE REQ - 113E - Velocity deviation error
SERVICE REQ - 113F - Lock error
SERVICE REQ - 122A - Overload error
SERVICE REQ - 122B - Over speed error
SERVICE REQ - 122C - Reversing error
SERVICE REQ - 122D - Driving time-out error
SERVICE REQ - 122E - Velocity deviation error
SERVICE REQ - 122F - Lock error
SERVICE REQ - 131B - Head driver (transmission gate) overheat error
SERVICE REQ - 1412 - Motor Life Error
SERVICE REQ - 141A - Overload error
SERVICE REQ - 141B - Over speed error
SERVICE REQ - 141C - Reversing error
SERVICE REQ - 141D - Driving time-out error
SERVICE REQ - 141E - Velocity deviation error
SERVICE REQ - 141F - Lock error
SERVICE REQ - 1431 - Ink selector life error
SERVICE REQ - 1432 - IC Holder life error
SERVICE REQ - 1433 - IS Unit position sensor error
SERVICE REQ - 1494 - Ink selector error
SERVICE REQ - 1496 - Ink selector sensor error detection
SERVICE REQ - 1497 - Switching time-out error
SERVICE REQ - 149D - Driving time-out error
SERVICE REQ - 150C - PG phase detection error
SERVICE REQ - 151A - Overload error
SERVICE REQ - 151B - Over speed error
SERVICE REQ - 151C - Reversing error
SERVICE REQ - 151D - Driving time-out error
SERVICE REQ - 151E - Velocity deviation error
SERVICE REQ - 151F - Lock error
SERVICE REQ - 1520 - Roll feed motor lock retry error
SERVICE REQ - 1521 - Roll feed sensor detect error
SERVICE REQ - 1523 - Roll sensor error
SERVICE REQ - 151A - Overload error
SERVICE REQ - 151B - Over speed error
SERVICE REQ - 151C - Reversing error
SERVICE REQ - 152D - Driving time-out error
SERVICE REQ - 152E - Velocity deviation error
SERVICE REQ - 152F - Lock error
SERVICE REQ - 1530 - hp detection error
SERVICE REQ - 1531 - Release Sensor error
SERVICE REQ - 153A - Overload error
SERVICE REQ - 153B - Over speed error
SERVICE REQ - 153C - Reversing error
SERVICE REQ - 153D - Driving time-out error
SERVICE REQ - 153E - Velocity deviation error
SERVICE REQ - 153F - Lock error
SERVICE REQ - 1540 - Cutter hp detection error
SERVICE REQ - 1541 - Cutter return error
SERVICE REQ - 1549 - Motor disconnection error
SERVICE REQ - 154A - Overload error
SERVICE REQ - 154B - Cutter Motor over speed error
SERVICE REQ - 154C - Cutter Motor reversing error
SERVICE REQ - 154D - Driving time-out error
SERVICE REQ - 154E - Velocity deviation error
SERVICE REQ - 154F - Lock error
SERVICE REQ - 1551 - Paper thickness determining error
SERVICE REQ - 155A - DCP Motor overload error
SERVICE REQ - 155B - DCP Motor over speed error
SERVICE REQ - 155C - DCP Motor reversing error
SERVICE REQ - 155D - DCP Motor driving time-out error
SERVICE REQ - 155E - DCP Motor velocity deviation error
SERVICE REQ - 155F - DCP Motor lock error
SERVICE REQ - 1561 - Paper thickness at power-on error
SERVICE REQ - 1562 - ASF Motor abnormal load detection error
SERVICE REQ - 156A - ASF Motor overload error
SERVICE REQ - 156B - ASF Motor over speed error
SERVICE REQ - 156C - ASF Motor reversing error
SERVICE REQ - 156D - ASF Motor driving time-out error
SERVICE REQ - 156E - ASF Motor velocity deviation error
SERVICE REQ - 156F - ASF Motor lock error
SERVICE REQ - 1571 - ASF Retard Roller Sensor operation error
SERVICE REQ - 1572 - ASF Pickup Roller operation error
SERVICE REQ - 1573 - ASF Assist Roller operation error
SERVICE REQ - 157A - ASF Sub Motor overload error
SERVICE REQ - 157B - ASF Sub Motor over speed error
SERVICE REQ - 157C - ASF Sub Motor reversing error
SERVICE REQ - 157D - ASF Sub Motor driving time-out error
SERVICE REQ - 157E - ASF Sub Motor velocity deviation error
SERVICE REQ - 157F - ASF Sub Motor lock error
SERVICE REQ - 1581 - Paper eject position error
SERVICE REQ - 1582 - ASF Edge Guide open/close error
SERVICE REQ - 158A - EG Motor overload error
SERVICE REQ - 158B - EG Motor over speed error
SERVICE REQ - 158C - EG Motor reversing error
SERVICE REQ - 158D - EG Motor driving time-out error
SERVICE REQ - 158E - EG Motor velocity deviation error
SERVICE REQ - 158F - EG Motor lock error
SERVICE REQ - 159A - ATC Motor overload error
SERVICE REQ - 159B - ATC Motor over speed error
SERVICE REQ - 159C - ATC Motor reversing error
SERVICE REQ - 159D - ATC Motor driving time-out error
SERVICE REQ - 159E - ATC Motor velocity deviation error
SERVICE REQ - 159F - ATC Motor lock error
SERVICE REQ - 1801 - AID voltage error
SERVICE REQ - 1A23 - Incorrect RTC data error
SERVICE REQ - 1A26 - RTC Access T/O error
SERVICE REQ - 1A37 - Thermistor error
SERVICE REQ - 1A38 - Transistor environmental temperature error
SERVICE REQ - 1A39 - Head error
SERVICE REQ - 1A41 - Head rank ID input error
SERVICE REQ - 1A50 - I2C communication error (Between elements on ASIC and MAIN)
SERVICE REQ - 1A51 - I2C communication error (Between elements on SUB and MAIN)
SERVICE REQ - 1ABx - Main Board communication error
SERVICE REQ - 1Fxx - ILS error (1)
SERVICE REQ - 2000 - NVRAM error
SERVICE REQ - 2002 - SDRAM error
SERVICE REQ - 2003 - FLASH BOOT SUM CHECK error
SERVICE REQ - 200A - F/W load error
SERVICE REQ - 200D - System interrupt watchdog time-out error
SpectroProofer Errors
01 - SpectroProofer uninstallation error
02 - Paper Eject Support uninstallation error
13 - Foreign material detection error in paper pressing
14 - Paper pressing origin position detection failure error
15 - CR hp Sensor no detection error
16 - Paper pressing system abnormal measurement value error
65 - Drying Fan lock detection error
80 - ILS calibration error
D5 - CR related drive error
D6 - Paper pressing related operating error
Epson 4xx0 Error Codes
Maintenance Requests Errors
MAINTENANCE REQ - 0002 - The number of CR movement cycles has reached predetermined value
MAINTENANCE REQ - 0008 - RTC backup battery shut off
MAINTENANCE REQ - 0040 - Pump counter has reached predetermined amount.
MAINTENANCE REQ - 0080 - Date is not set
MAINTENANCE REQ - 0088 - RTC backup battery is not installed.
MAINTENANCE REQ - 0100 - RTC backup battery pressure is temporally low.
MAINTENANCE REQ - 0200 - The number of ASF paper feeding has reached predetermined value.
Service Request Errors
SERVICE REQ - 00000101 - CR Motor life
SERVICE REQ - 00010000 - PF Motor Encoder check error
SERVICE REQ - 00010001 - PF Motor out of step
SERVICE REQ - 00010002 - PF Motor over current
SERVICE REQ - 00010003 - PF Motor in-position time-out
SERVICE REQ - 00010004 - CR Motor Encoder check error
SERVICE REQ - 00010005 - CR Motor out of step
SERVICE REQ - 00010006 - CR Motor over current
SERVICE REQ - 00010007 - CR Motor in-position time-out
SERVICE REQ - 00010008 - Servo interrupt watchdog time-out
SERVICE REQ - 00010009 - System interrupt watchdog time-out
SERVICE REQ - 0001000A - CR axis detection error
SERVICE REQ - 0001000C - PG axis detection error
SERVICE REQ - 0001000F - CR Motor PWM output faulty
SERVICE REQ - 00010010 - PF Motor PWM output faulty
SERVICE REQ - 00010012 - CR overload (high sensitivity) error
SERVICE REQ - 00010013 - PR overload (high sensitivity) error
SERVICE REQ - 0001001B - Head driver (TG) temperature error
SERVICE REQ - 0001001D - CR servo parameter error
SERVICE REQ - 0001001E - PF servo parameter error
SERVICE REQ - 00010020 - CSIC reed/right error
SERVICE REQ - 00010022 - Ink type error (setting on printer body side)
SERVICE REQ - 00010023 - RTC analysis error
SERVICE REQ - 00010025 - CSIC ROM communication error
SERVICE REQ - 00010026 - RTC communication error
SERVICE REQ - 00010028 - Head error
SERVICE REQ - 00010029 - Unidentified NMI
SERVICE REQ - 0001002A - CR ASIC ECU error
SERVICE REQ - 0001002B - PF ASIC ECU error
SERVICE REQ - 0001002D - Cleaning Unit work life error
SERVICE REQ - 0001002F - 360 DPI writing time out error
SERVICE REQ - 00010030 - Multi Sensor failure
SERVICE REQ - 00010031 - ASF phase detection error
SERVICE REQ - 00010032 - ASF drive switch error
SERVICE REQ - 00010033 - Eject phase detection error
SERVICE REQ - 00010034 - Eject movement error
SERVICE REQ - 00010035 - Pump phase detection error
SERVICE REQ - 00010036 - Type-B board installation error
SERVICE REQ - 00010037 - Head thermistor error
SERVICE REQ - 00010038 - Transistor thermistor error
SERVICE REQ - 00010039 - PG adjustment value incorrect overwrite error
SERVICE REQ - 0001003A - PG adjustment value outside range error
SERVICE REQ - 0001003B - Cutter installation error 1
SERVICE REQ - 0001003C - Cutter installation error 2
SERVICE REQ - 0001003D - Cutter installation error 3
SERVICE REQ - 00020000 - NVRAM error
SERVICE REQ - 00020002 - SDRAM error
SERVICE REQ - 00020003 - BOOT program SUM error
SERVICE REQ - 00020009 - Flash memory SUM error
SERVICE REQ - 0002000A - Program load error
SERVICE REQ - 0002000B - Internal memory shortage error
SERVICE REQ - 100000E0 - CPU address error (load misalignment)
SERVICE REQ - 10000100 - CPU address error (storage misalignment)
SERVICE REQ - 10000180 - CPU reserve command code exception error
SERVICE REQ - 100001A0 - CPU slot illegal command exception error
SERVICE REQ - 100001C0 - AC disruption
SERVICE REQ - 100005C0 - CPU DMA address error
SERVICE REQ - 10000xxx - CPU error
SERVICE REQ - 0003xxxx - Debug error code
SERVICE REQ - 0Dxxxxxx - Debug error code
SERVICE REQ - 0Exxxxxx - RTC timer off error
Epson 4000 Error Codes
Maintenance Requests Errors
MAINTENANCE REQ - 0002 - The number of CR movement cycles has reached predetermined value
MAINTENANCE REQ - 0008 - RTC backup battery shut off
MAINTENANCE REQ - 0040 - Pump counter has reached predetermined amount.
MAINTENANCE REQ - 0080 - Date is not set
MAINTENANCE REQ - 0088 - RTC backup battery is not installed.
MAINTENANCE REQ - 0100 - RTC backup battery pressure is temporally low.
MAINTENANCE REQ - 0200 - The number of ASF paper feeding has reached predetermined value.
Service Request Errors
SERVICE REQ - 00000101 - CR Motor life
SERVICE REQ - 00010000 - PF Motor Encoder check error
SERVICE REQ - 00010001 - PF Motor out of step
SERVICE REQ - 00010002 - PF Motor over current
SERVICE REQ - 00010003 - PF Motor in-position time-out
SERVICE REQ - 00010004 - CR Motor Encoder check error
SERVICE REQ - 00010005 - CR Motor out of step
SERVICE REQ - 00010006 - CR Motor over current
SERVICE REQ - 00010007 - CR Motor in-position time-out
SERVICE REQ - 00010008 - Servo interrupt watchdog time-out
SERVICE REQ - 00010009 - System interrupt watchdog time-out
SERVICE REQ - 0001000A - CR axis detection error
SERVICE REQ - 0001000C - PG axis detection error
SERVICE REQ - 0001000F - CR Motor PWM output faulty
SERVICE REQ - 00010010 - PF Motor PWM output faulty
SERVICE REQ - 0001001B - Head driver (TG) temperature error
SERVICE REQ - 0001001D - CR servo parameter error
SERVICE REQ - 0001001E - PF servo parameter error
SERVICE REQ - 00010020 - CSIC reed/right error
SERVICE REQ - 00010022 - Ink type error (setting on printer body side)
SERVICE REQ - 00010023 - RTC analysis error
SERVICE REQ - 00010025 - CSIC ROM communication error
SERVICE REQ - 00010026 - RTC communication error
SERVICE REQ - 00010028 - Head error
SERVICE REQ - 00010029 - Unidentified NMI
SERVICE REQ - 00001002A - CR ASIC ECU error
SERVICE REQ - 0001002B - PF ASIC ECU error
SERVICE REQ - 0001002D - Cleaning Unit work life error
SERVICE REQ - 0001002F - 360 DPI writing time out error
SERVICE REQ - 00010030 - Multi Sensor failure
SERVICE REQ - 00010031 - ASF phase detection error
SERVICE REQ - 00010032 - ASF drive switch error
SERVICE REQ - 00010033 - Eject phase detection error
SERVICE REQ - 00010034 - Eject movement error
SERVICE REQ - 00010035 - Pump phase detection error
SERVICE REQ - 00010036 - Type-B board installation error
SERVICE REQ - 00010037 - Head thermistor error
SERVICE REQ - 00010038 - Transistor thermistor error
SERVICE REQ - 00010039 - PG adjustment value incorrect overwrite error
SERVICE REQ - 0001003A - PG adjustment value outside range error
SERVICE REQ - 0001003B - Cutter installation error 1
SERVICE REQ - 0001003C - Cutter installation error 2
SERVICE REQ - 0001003D - Cutter installation error 3
SERVICE REQ - 00020000 - NVRAM error
SERVICE REQ - 00020002 - SDRAM error
SERVICE REQ - 00020003 - BOOT program SUM error
SERVICE REQ - 00020009 - Flash memory SUM error
SERVICE REQ - 0002000A - Program load error
SERVICE REQ - 0002000B - Internal memory shortage error
SERVICE REQ - 100000E0 - CPU address error (load misalignment)
SERVICE REQ - 10000100 - CPU address error (storage misalignment)
SERVICE REQ - 10000180 - CPU reserve command code exception error
SERVICE REQ - 100001A0 - CPU slot illegal command exception error
SERVICE REQ - 100001C0 - AC disruption
SERVICE REQ - 100005C0 - CPU DMA address error
SERVICE REQ - 10000xxx - CPU error
SERVICE REQ - 0003xxxx - Debug error code
SERVICE REQ - 0Dxxxxxx - Debug error code
Epson 10000 10600 Error Codes
Maintenance Requests Errors
MAINTENANCE REQ - 0100 - Indicates small quantity of remaining waste ink material absorption.
MAINTENANCE REQ - 0101 - The CR motor reached the 3% remaining to the life.
MAINTENANCE REQ - 0102 - Auto nozzle check error
MAINTENANCE REQ - 0103 - Backup battery for RTC (real time clock) life expired.
MAINTENANCE REQ - 0104 - Dot missing detector error
Service Request Errors
SERVICE REQ - 00000100 - Waste ink pads are full
SERVICE REQ - 00000101 - CR motor life (Ink tubes also reached their life)
SERVICE REQ - 00000102 - Nozzle check error compulsory continuity
SERVICE REQ - 00000103 - RTC backup battery end
SERVICE REQ - 00000104 - Auto print head optimization system
SERVICE REQ - 00000105 - Head unit life end
SERVICE REQ - 00000106 - Cleaning unit life end
SERVICE REQ - 00010000 - PF motor/ encoder check error
SERVICE REQ - 00010001 - PF motor step-out
SERVICE REQ - 00010002 - PF motor/overcurrent
SERVICE REQ - 00010003 - PF motor/ in position time-out error
SERVICE REQ - 00010004 - CR motor/ encoder check error
SERVICE REQ - 00010005 - CR motor step-out
SERVICE REQ - 00010006 - CR motor/overcurrent
SERVICE REQ - 00010007 - CR motor/ in position time-out error
SERVICE REQ - 00010008 - Servo interruption watch dog time out error
SERVICE REQ - 00010009 - System interruption watch dog time out error
SERVICE REQ - 0001000A - CR origin sensor mulfanction
SERVICE REQ - 0001000B - PF origin sensor mulfanction
SERVICE REQ - 0001000C - HS origin sensor mulfanction
SERVICE REQ - 0001000D - Cover sensor mulfanction
SERVICE REQ - 0001000E - Cover sensor mulfanction
SERVICE REQ - 0001000F - CR motor over heat (PWM output malfunction)
SERVICE REQ - 00010010 - PF motor over heat (PWM output malfunction)
SERVICE REQ - 00010011 - Paper jam error
SERVICE REQ - 00010012 - Cap origin error
SERVICE REQ - 00010013 - Providing system origin error
SERVICE REQ - 00010014 - Pressurization error
SERVICE REQ - 00010015 - Liquid sensor overflow (K)
SERVICE REQ - 00010016 - Liquid sensor overflow(C)
SERVICE REQ - 00010017 - Liquid sensor overflow (M)
SERVICE REQ - 00010018 - Liquid sensor overflow (LC)
SERVICE REQ - 00010019 - Liquid sensor overflow (LM)
SERVICE REQ - 0001001A - Liquid sensor overflow (Y)
SERVICE REQ - 0001001B - Head driver (TG) temperature error
SERVICE REQ - 0001001C - FS origin (Suction fan shutter home position) error
SERVICE REQ - 0001001D - CR servo parameter error
SERVICE REQ - 0001001E - PF servo parameter error
SERVICE REQ - 00010020 - CSIC card read/write error
SERVICE REQ - 00010021 - Starter cartridge error
SERVICE REQ - 00010022 I- nk type NVRAM status error
SERVICE REQ - 00010023 - RTC operation malfunction
SERVICE REQ - 00010024 - Module communication time-out error
SERVICE REQ - 00010025 - CSIC EEROR access error
SERVICE REQ - 00010026 - RTC access error
SERVICE REQ - 00010027 - Pressure pump small leak error
SERVICE REQ - 00010028 - During cleaning, pressure pump small leak error
SERVICE REQ - 00020000 - NVRAM error
SERVICE REQ - 00020001 - NVRAM check sum error
SERVICE REQ - 00020002 - SDRAM error
SERVICE REQ - 00020003 - Flash memory sum error
SERVICE REQ - 00020004 - ASIC illegal version error
SERVICE REQ - 00020005 - Firmware ASIC mismatching error (Version:A)
SERVICE REQ - 00020006 - Firmware ASIC mismatching error (Version:B)
SERVICE REQ - 00020007 - Head/ASIC mismatch error
SERVICE REQ - 00020009 - Flash memory check sum error
SERVICE REQ - 0002000B - Memory insufficient error
SERVICE REQ - 0002000C - Review error
SERVICE REQ - 00030000 - 00030013 - Debug error
SERVICE REQ - 00030015 - Ink supply defective (K)
SERVICE REQ - 00030016 - Ink supply defective (C)
SERVICE REQ - 00030017 - Ink supply defective (M)
SERVICE REQ - 00030018 - Ink supply defective (LC)
SERVICE REQ - 00030019 - Ink supply defective (LM)
SERVICE REQ - 0003001A - Ink supply defective (Y)
SERVICE REQ - 0003001B - GAP adjustment range error
SERVICE REQ - 0003001C - Timeout in case of no print finishing with ASIC
SERVICE REQ - D0120013 - Module comminication error
SERVICE REQ - D012001E - Engine side ASIC command transmission over flow
SERVICE REQ - D012001F - Engine side ASIC command receiption over error
SERVICE REQ - D0xxxxxx - Program error
SERVICE REQ - 10000E0 - CPU address error
SERVICE REQ - 1000100 - CPU address error
SERVICE REQ - 10000180 - CPU reservation instruction code exception error
SERVICE REQ - 100001A0 - CPU Slot unfair command exception error
SERVICE REQ - 100005C0 - CPU DMA address error
SERVICE REQ - 10000xxx - CPU illegal trap
SERVICE REQ - FFFFxxxx - OS kernel detection error
epson常見(jiàn)故障問(wèn)題解答 2015-9-8 7:11:04
1101 cr 馬達(dá)壽命到了
epson7910打印漏墨 手機(jī)用戶(hù)171.82.*.* 2020-12-25 152E
epson7910打印臟 周寵奩 2020-12-27 服務(wù)請(qǐng)求-152E-速度偏差錯(cuò)誤