佳能 5250I打印機(jī)出現(xiàn)E00003-0000怎么解決
定影問(wèn)題
佳能5250園區(qū)維修點(diǎn) ply030916it 2021/9/24 Code E003-0000定影出問(wèn)題了
Description The main thermistor reading is lower than 140C when paper is moved
Causes The fixing film unit is faulty (i.e., the main thermistor (TH1) has poor contact , has an open circuit; the fixing heater is faulty). The main power supply PCB is faulty. The DC controller PCB is faulty. Caution To clear the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR.
定影問(wèn)題
佳能5250園區(qū)維修點(diǎn) ply030916it 2021/9/24 Code E003-0000定影出問(wèn)題了
Description The main thermistor reading is lower than 140C when paper is moved
Causes The fixing film unit is faulty (i.e., the main thermistor (TH1) has poor contact , has an open circuit; the fixing heater is faulty). The main power supply PCB is faulty. The DC controller PCB is faulty. Caution To clear the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR.