震旦218打印機出現(xiàn)C-2152是什么原因
更新時間:2024/11/19 8:58:47,view:704震旦218蘇州震旦打印機售后服務中心客服熱線69616769,蘇州震旦售后電話,震旦售后網(wǎng)點, 震旦218顯示c2152怎么返回, 震旦ADC218顯示C-2152, 震旦ADC218出C2152, 震旦adc218檢測故障c-2551, 震旦adc218錯誤代碼c2652,維修視頻
蘇州維修電話696l6769,維修現(xiàn)場維修
Code C2152
轉(zhuǎn)印帶縮回操作期間,轉(zhuǎn)印帶縮回傳感器無法在轉(zhuǎn)印
帶縮回離合器開啟后的預定時間間隔內(nèi)檢測到轉(zhuǎn)印帶
是否位于其縮回位置。
轉(zhuǎn)印帶加壓操作期間,轉(zhuǎn)印帶縮回傳感器無法在轉(zhuǎn)印
帶離合器開啟后的預定時間間隔內(nèi)檢測到轉(zhuǎn)印帶是否
位于其加壓位置。
Description
Transfer belt pressure welding alienation
The transfer belt retraction sensor does not detect “switch from retraction to pressure” within a given period time after transfer belt retraction clutch has stared engagement. The transfer belt retraction sensor does not detect “switch from pressure to retraction” within a given period time after transfer belt retraction clutch has stared engagement.
Remedy
1 Check the connector between M1-PRCB CN14 for proper connection and correct as necessary.
2 Check the connector of M1 for proper drive coupling and correct as necessary.
3 Check the connector between PS39-relay CN124-PRCB CN3 for proper connection and correct as necessary.
4 Check the connector between CL5-relay CN103-PRCB CN24 for proper connection and correct as necessary.
5 PS39 I/O check, sensor check PRCB CN3-15 (ON)
6 CL5 operation check PRCB CN24-4 (ON)
7 M1 operation check PRCB CN14-2 (REM) PRCB CN14-5 (LOCK) C-2 to 5
8 Change M1.
9 PRCB ICP5 conduction check.
10 Change PRCB.
震旦218 打印機出現(xiàn)C-2152是什么原因
Code C2152
轉(zhuǎn)印帶縮回操作期間,轉(zhuǎn)印帶縮回傳感器無法在轉(zhuǎn)印
帶縮回離合器開啟后的預定時間間隔內(nèi)檢測到轉(zhuǎn)印帶
是否位于其縮回位置。
轉(zhuǎn)印帶加壓操作期間,轉(zhuǎn)印帶縮回傳感器無法在轉(zhuǎn)印
帶離合器開啟后的預定時間間隔內(nèi)檢測到轉(zhuǎn)印帶是否
位于其加壓位置。
Description
Transfer belt pressure welding alienation
The transfer belt retraction sensor does not detect “switch from retraction to pressure” within a given period time after transfer belt retraction clutch has stared engagement. The transfer belt retraction sensor does not detect “switch from pressure to retraction” within a given period time after transfer belt retraction clutch has stared engagement.
Remedy
1 Check the connector between M1-PRCB CN14 for proper connection and correct as necessary.
2 Check the connector of M1 for proper drive coupling and correct as necessary.
3 Check the connector between PS39-relay CN124-PRCB CN3 for proper connection and correct as necessary.
4 Check the connector between CL5-relay CN103-PRCB CN24 for proper connection and correct as necessary.
5 PS39 I/O check, sensor check PRCB CN3-15 (ON)
6 CL5 operation check PRCB CN24-4 (ON)
7 M1 operation check PRCB CN14-2 (REM) PRCB CN14-5 (LOCK) C-2 to 5
8 Change M1.
9 PRCB ICP5 conduction check.
10 Change PRCB.