理光1811跳代碼 打印機(jī)修理王 2021/9/22 Code: SC542定影器故障
Description:
Fusing Reload Temperature Error (Fatal Error) (C8)
Causes:
After starting up , during operation the machine detected after 5 readings at 1.5 sec. intervals that the hot roller was 5 below the reload (operating) temperature. Unstable input voltage Fusing thermistor deformed , out of position Fusing lamp harness loose, broken, defective Fusing lamp defective Fusing unit defective
Remedy:
Use high quality power source Check the Fusing thermistor position , it harness connection Check the Fusing lamp , it harness connection Replace Fusing unit
理光常見故障問題解答 2014-11-28 10:45:23
求助!
理光1811跳代碼 打印機(jī)修理王 2021/9/22 Code: SC542定影器故障
Description:
Fusing Reload Temperature Error (Fatal Error) (C8)
Causes:
After starting up , during operation the machine detected after 5 readings at 1.5 sec. intervals that the hot roller was 5 below the reload (operating) temperature. Unstable input voltage Fusing thermistor deformed , out of position Fusing lamp harness loose, broken, defective Fusing lamp defective Fusing unit defective