柯尼卡美能達(dá)283故障代碼C-4501
柯尼卡美能達(dá)283故障代碼C-4501
美能達(dá)283打印臟 GUILING17131720 2021/11/2 蘇州美能達(dá)283維修服務(wù)中心地址查詢(xún) Code C4501
Description
Laser malfunction
SOS signal is not detected even after the lapse of a given period of time after staring the laser output. SOS signal is not detected for a given period of time during printing , IDC sensor adjustment.
Remedy
1 Check the connector between PH unit- PHREYB CN5 for proper connection , correct as necessary.
2 Check the connector between PHREYB CN2-PRCB CN25 for proper connection , correct as necessary.
3 Change PH unit.
4 PRCB ICP12 conduction check.
5 Change PHREYB.
6 Change PRCB.
美能達(dá)283打印臟 GUILING17131720 2021/11/2 蘇州美能達(dá)283維修服務(wù)中心地址查詢(xún) Code C4501
Description
Laser malfunction
SOS signal is not detected even after the lapse of a given period of time after staring the laser output. SOS signal is not detected for a given period of time during printing , IDC sensor adjustment.
Remedy
1 Check the connector between PH unit- PHREYB CN5 for proper connection , correct as necessary.
2 Check the connector between PHREYB CN2-PRCB CN25 for proper connection , correct as necessary.
3 Change PH unit.
4 PRCB ICP12 conduction check.
5 Change PHREYB.
6 Change PRCB.
熱門(mén)圖文