佳能e000065-0001
更新時(shí)間:2024/11/21 2:48:39,view:111佳能打印機(jī)蘇州佳能打印機(jī)售后服務(wù)中心客服熱線69616769,蘇州佳能售后電話,佳能售后網(wǎng)點(diǎn),
佳能e000065-0001
佳能c2225售后技術(shù)論壇 123 2018/3/12 11:25:41 佳能復(fù)印機(jī)6275出現(xiàn)代碼E000065-0001是什么問(wèn)題,怎么解決
佳能c2225售后技術(shù)論壇 呂諑匪 2018/10/17 20:56:39 Code E065-0001
Description Error in detection of abnormal M charging AC current value
During the paper interval simple discharge current control, a current value that is higher than the target of
500[uA] is detected
Remedy Error in output of charging high voltage, Drum Unit error or environment control error
1. COPIER > DISPLAY > ANALOG; check if the TEMP value and the HUM value are matched with the environment temperature. When the values are dramatically mismatched (Lager than
15degrees Celsius)
2-1. Check the harness and connector between the DC Controller (UN09/ J206) and the Environment Sensor (UN45)
3-1. Replace the Environment Sensor (UN45)
4-1. Replace the DC Controller (UN9) When the values are matched
2-2. Check the state of the charging high voltage contact point
3-2. Replace the Drum Unit (M)
4-2. Check the harness and connector between the DC Controller PCB (UN09/ J21) and the Primary Charging High Voltage PCB (UN06/ J441, J442)
5-2. Replace the Primary Charging High Voltage PCB (UN06)
6-2. Replace the DC Controller PCB (UN09)
佳能c2225售后技術(shù)論壇 123 2018/3/12 11:25:41 佳能復(fù)印機(jī)6275出現(xiàn)代碼E000065-0001是什么問(wèn)題,怎么解決
佳能c2225售后技術(shù)論壇 呂諑匪 2018/10/17 20:56:39 Code E065-0001
Description Error in detection of abnormal M charging AC current value
During the paper interval simple discharge current control, a current value that is higher than the target of
500[uA] is detected
Remedy Error in output of charging high voltage, Drum Unit error or environment control error
1. COPIER > DISPLAY > ANALOG; check if the TEMP value and the HUM value are matched with the environment temperature. When the values are dramatically mismatched (Lager than
15degrees Celsius)
2-1. Check the harness and connector between the DC Controller (UN09/ J206) and the Environment Sensor (UN45)
3-1. Replace the Environment Sensor (UN45)
4-1. Replace the DC Controller (UN9) When the values are matched
2-2. Check the state of the charging high voltage contact point
3-2. Replace the Drum Unit (M)
4-2. Check the harness and connector between the DC Controller PCB (UN09/ J21) and the Primary Charging High Voltage PCB (UN06/ J441, J442)
5-2. Replace the Primary Charging High Voltage PCB (UN06)
6-2. Replace the DC Controller PCB (UN09)