佳能2002g復(fù)印機(jī)報(bào)E014-0000錯(cuò)誤代碼 佳能2002g 秦矣筌 2018/11/17 17:33:49 Code E014-000
Description After the fixing motor drive signal is generated, the clock signal does not arrive within1.3 sec
Causes The fixing motor (M19) is faulty. The DC controller PCB is faulty.
Remedy
1. Connector Is the connector of the fixing motor connected? NO: Connect the connector.
2. Main power supply PCB Is the drive voltage (24 V) of the fixing motor supplied by the main power supply PCB? Main power supply PCB: between J202-3 (24VU1-S) and J202-4 (OVU1) NO: Replace the main power supply PCB.
3. Fixing motor (M19), DC controller PCB Press the Start key. Is the lock signal of the fixing motor present at the connector (J312) on the DC controller PCB? Lock signal: J312-B4 (FSRM_LOCK*) the DC controller PCB change from 0 to about5 V? YES: Replace the fixing motor. NO: Replace the DC controller PCB.
Description After the fixing motor drive signal is generated, the clock signal does not arrive within1.3 sec
Causes The fixing motor (M19) is faulty. The DC controller PCB is faulty.
Remedy
1. Connector Is the connector of the fixing motor connected? NO: Connect the connector.
2. Main power supply PCB Is the drive voltage (24 V) of the fixing motor supplied by the main power supply PCB? Main power supply PCB: between J202-3 (24VU1-S) and J202-4 (OVU1) NO: Replace the main power supply PCB.
3. Fixing motor (M19), DC controller PCB Press the Start key. Is the lock signal of the fixing motor present at the connector (J312) on the DC controller PCB? Lock signal: J312-B4 (FSRM_LOCK*) the DC controller PCB change from 0 to about5 V? YES: Replace the fixing motor. NO: Replace the DC controller PCB.
熱門圖文