hpcp5525故障代碼59.00.f0
更新時間:2024/10/29 16:17:13,view:201hp打印機hpcp5525蘇州hp打印機售后服務中心客服熱線69616769,蘇州hp售后電話,hp售后網點, HPcp5525開機出現(xiàn)Apnehoyredorogfjernfastkjortpapir,維修視頻
hpcp5525故障代碼59.00.f0 電機和齒輪組轉不動都會出現(xiàn)59.F0
The sensor flag/lever is stuck in the up position which causes the 59.F0 error
59.F0 error ITB Contact Alienation error
Code 59.F0
Display
59.F0 ERROR
Description Transfer alienation failure
Remedy
1. Verify that the ITB is installed.
2. Reconnect the primary-transfer disengagement sensor J19, and connector J128 on the DC controller PCA .
3. Run the sensor test in the sensor monitor mode to verify that the primary transfer disengagement sensor is functioning properly. If not, replace the primary transfer disengagement sensor.
4. Perform the alienation drive component test in the DIAGNOSTICS menu. If not, replace the fuser motor.
蘇州hp打印機維修站電話696l6769,維修,售后服務
The sensor flag/lever is stuck in the up position which causes the 59.F0 error
59.F0 error ITB Contact Alienation error
Code 59.F0
Display
59.F0 ERROR
Description Transfer alienation failure
Remedy
1. Verify that the ITB is installed.
2. Reconnect the primary-transfer disengagement sensor J19, and connector J128 on the DC controller PCA .
3. Run the sensor test in the sensor monitor mode to verify that the primary transfer disengagement sensor is functioning properly. If not, replace the primary transfer disengagement sensor.
4. Perform the alienation drive component test in the DIAGNOSTICS menu. If not, replace the fuser motor.
蘇州hp打印機維修站電話696l6769,維修,售后服務