hp3525打印機顯示59.F0

hp3525打印機顯示59.F0電機和齒輪組轉(zhuǎn)不動都會出現(xiàn)59.F0
The sensor flag/lever is stuck in the up position which causes the 59.F0 error
59.F0 error ITB Contact Alienation error
Code 59.F0
Display
59.F0 ERROR
Description Transfer alienation failure
Remedy
1. Verify that the ITB is installed.
2. Reconnect the primary-transfer disengagement sensor J19, and connector J128 on the DC controller PCA .
3. Run the sensor test in the sensor monitor mode to verify that the primary transfer disengagement sensor is functioning properly. If not, replace the primary transfer disengagement sensor.
4. Perform the alienation drive component test in the DIAGNOSTICS menu. If not, replace the fuser motor.