將正常關(guān)機(jī)時(shí)固定打印頭的哪個(gè)件---字車鎖(見下圖)用橡皮筋綁下去即可.
最好拆除字車鎖
其他,
如下代碼表解釋的,這也有可能是字車輪 皮帶輪 CR光柵 傳感器 主板 電機(jī) 等部件問題 請實(shí)際情況實(shí)際 對待
ErrorCode; 00010005 Description; CR Motor out of step
Explanation During CR Motor operation, there may be a case where the encoder pulse signal within the specified range is not input within a specified period of time or the pulse width is extremely long or short. In such a case, the CR Motor is judged to be out-of-step, so that this message is displayed and the printer stops operating.
Cause of trouble Defective CR Motor.
CR Motor driver damage (42V system short)
Broken temperature fuse for Cutter Solenoid.
Points to be checked 1. CR Scale is disconnected from CR Encoder Sensor.
2. The CR Encoder and the CR scale must be free from dust and dirt or any other foreign matters.
3. Execute encoder checking by the Service Manual "1.4.6.1 Self Testing Menu (SELF TESTING)" (p.91) in "Maintenance Mode 2".
4. The CR Timing Belt must be free from any defects and the belt must be in proper tension.
5. Execute the CR_hp Sensor checking by the "1.4.6.1 Self TestingMenu (SELF TESTING)" (p.91) in "Maintenance Mode 2".
6. The Carriage Unit must slide smoothly, free from undue load.
7. Measure the resistance value of the CR Motor. (17.9 ± 10% [Ω])
8. All the harness must be connected properly and free from short circuit or broken wire.
Remedy 1. Check to see if the CR Scale for detection of the encoder pulse is removed
2. Check for dirt, paper dust or damage to the CR Scale.
3. Perform the CR Timing Belt Tension Adjustment (Service Manual p.376)
4. Replace the CR Encoder Sensor (p.280)
5. Replace the CR_hp Sensor (p.276)
6. Replace the Motor Assy., CR (p.270)
7. Replace the C593 MAIN Board (p.226)
8. Replace the Cutter Solenoid