bizhub7719復(fù)印機出現(xiàn)C3752
Code C3752 (定影高溫異常)
Description
Abnormally high fusing temperature (sub)
- The temperature detected by the thermistor/2 (TH2) is over the specified temperature for more than the specified period of time after power is turned ON.
Remedy
1 Check the fusing unit for correct installation.
2 Check the open/close operation of the right door.
3 Check the fusing unit, DCPU and MFPB for proper connection and correct or change as necessary.
4 Change fusing unit.
5 Change MFPB.