柯尼卡美能達(dá)283故障代碼C-3821
更新時間:2025/2/2 8:54:24,view:188美能達(dá)打印機(jī)283蘇州美能達(dá)打印機(jī)售后服務(wù)中心客服熱線69616769,蘇州美能達(dá)售后電話,美能達(dá)售后網(wǎng)點,
柯尼卡美能達(dá)283故障代碼C-3821
美能達(dá)283不開機(jī) 加粉王者 2021/11/12 Code C3821 (定影低溫錯誤)
Description
Fusing abnormally low temperature detection (heating side)
The heating roller thermistor continues to detect a temperature lower than a predetermined one for a predetermined period of time.
In the states other than a warm-up operation, a zero cross signal cannot be detected after the lapse of a predetermined period of time after the fusing heater is turned ON, OFF.
The power supply frequency cannot be detected.
Remedy
1 Check the fusing unit for correct installation (whether it is secured in position).
2 Check the open/close operation of the upper right door.
3 Check the fusing unit, PRCB,DCPU for proper connection,correct, change as necessary.
4 Change fusing unit.
5 Change PRCB.
6 Change DCPU.
![](http://www.ceo99999.com.cn/images/touxiang/26.jpg)
Description
Fusing abnormally low temperature detection (heating side)
The heating roller thermistor continues to detect a temperature lower than a predetermined one for a predetermined period of time.
In the states other than a warm-up operation, a zero cross signal cannot be detected after the lapse of a predetermined period of time after the fusing heater is turned ON, OFF.
The power supply frequency cannot be detected.
Remedy
1 Check the fusing unit for correct installation (whether it is secured in position).
2 Check the open/close operation of the upper right door.
3 Check the fusing unit, PRCB,DCPU for proper connection,correct, change as necessary.
4 Change fusing unit.
5 Change PRCB.
6 Change DCPU.