施樂4110出042-332
更新時間:2025/1/21 8:30:21,view:90施樂打印機4110蘇州施樂打印機售后服務(wù)中心客服熱線69616769,蘇州施樂售后電話,施樂售后網(wǎng)點, 施樂4110代碼091311, 施樂4110檢測不到紙盒, 施樂4110打印小字不清晰, 施樂4110代碼016-799, 施樂4110現(xiàn)代碼124一373,維修視頻
施樂4110出042-332
施樂4110 鄭鈣接 2018/11/21 21:32:29 Code
042-332
Description
Developer Fan (Process Fan 1) Failure The Developer Fan (Process 1 Fan) is having rotation error.
Causes
• MCU PWB, PL 12.1.15 • Developer Fan, PL 12.2.16 • Main Harness Assembly, PL 12.3.1
Remedy
1. Check the Developer Fan operation. Perform DC330 Component Control [042-002] to check the operation of the Developer Fan. Is the Belt Retract Motor operating properly? Replace the MCU PWB. Go to step 2.
2. Check the installation of the Developer Fan. Manually rotate the Developer Fan. Does the Fan rotate? Reinstall the Developer Fan. Go to step 3.
3. Check the connection between the Developer Fan and MCU PWB. Are the connectors P/J465 and P/J4652B connected securely? Go to step 4. Connect the connectors P/J465 and P/J4652B.
4. Check the conductivity between the Developer Fan and MCU PWB. Is the connection between P/J4652B <=> P/J465 conducting properly? Replace the Developer Fan. Replace the Main Harness Assembly.
![](http://www.ceo99999.com.cn/re.jpg)
042-332
Description
Developer Fan (Process Fan 1) Failure The Developer Fan (Process 1 Fan) is having rotation error.
Causes
• MCU PWB, PL 12.1.15 • Developer Fan, PL 12.2.16 • Main Harness Assembly, PL 12.3.1
Remedy
1. Check the Developer Fan operation. Perform DC330 Component Control [042-002] to check the operation of the Developer Fan. Is the Belt Retract Motor operating properly? Replace the MCU PWB. Go to step 2.
2. Check the installation of the Developer Fan. Manually rotate the Developer Fan. Does the Fan rotate? Reinstall the Developer Fan. Go to step 3.
3. Check the connection between the Developer Fan and MCU PWB. Are the connectors P/J465 and P/J4652B connected securely? Go to step 4. Connect the connectors P/J465 and P/J4652B.
4. Check the conductivity between the Developer Fan and MCU PWB. Is the connection between P/J4652B <=> P/J465 conducting properly? Replace the Developer Fan. Replace the Main Harness Assembly.