佳能2002G一卡紙就出現(xiàn)錯誤代碼E014-0000
更新時間:2024/11/15 9:40:41,view:363佳能打印機2002G蘇州佳能打印機售后服務(wù)中心客服熱線69616769,蘇州佳能售后電話,佳能售后網(wǎng)點, 佳能2002gE000-0000怎么了, 佳能2002g打印機顯示缺紙怎么辦, 復(fù)印機佳能2002G出故障代碼E0000000, 佳能2002g報E0000, 佳能2002g顯示E002.0000,維修視頻
佳能2002G一卡紙就出現(xiàn)錯誤代碼E014-0000 佳能2002g 許兆撾 2018/11/17 17:34:33 Code E014-000
Description After the fixing motor drive signal is generated, the clock signal does not arrive within1.3 sec
Causes The fixing motor (M19) is faulty. The DC controller PCB is faulty.
Remedy
1. Connector Is the connector of the fixing motor connected? NO: Connect the connector.
2. Main power supply PCB Is the drive voltage (24 V) of the fixing motor supplied by the main power supply PCB? Main power supply PCB: between J202-3 (24VU1-S) and J202-4 (OVU1) NO: Replace the main power supply PCB.
3. Fixing motor (M19), DC controller PCB Press the Start key. Is the lock signal of the fixing motor present at the connector (J312) on the DC controller PCB? Lock signal: J312-B4 (FSRM_LOCK*) the DC controller PCB change from 0 to about5 V? YES: Replace the fixing motor. NO: Replace the DC controller PCB.
Description After the fixing motor drive signal is generated, the clock signal does not arrive within1.3 sec
Causes The fixing motor (M19) is faulty. The DC controller PCB is faulty.
Remedy
1. Connector Is the connector of the fixing motor connected? NO: Connect the connector.
2. Main power supply PCB Is the drive voltage (24 V) of the fixing motor supplied by the main power supply PCB? Main power supply PCB: between J202-3 (24VU1-S) and J202-4 (OVU1) NO: Replace the main power supply PCB.
3. Fixing motor (M19), DC controller PCB Press the Start key. Is the lock signal of the fixing motor present at the connector (J312) on the DC controller PCB? Lock signal: J312-B4 (FSRM_LOCK*) the DC controller PCB change from 0 to about5 V? YES: Replace the fixing motor. NO: Replace the DC controller PCB.