佳能5255打印機代碼E000020-0204什么錯誤
更新時間:2025/2/7 4:45:33,view:128佳能5255蘇州佳能打印機售后服務(wù)中心客服熱線69616769,蘇州佳能售后電話,佳能售后網(wǎng)點, 佳能5255 0490, 打印機佳能C5255報錯E00003-0002, 佳能C5255載體加多少合適, 佳能5255復印機錯誤代碼0191, 佳能c5255和富士施樂2020,維修視頻
佳能5255打印機代碼E000020-0204什么錯誤
佳能5255 cyqq 2019-3-4 怎么回事
佳能5255 楊壇騅 2019-3-13 Code E000020-0204
Description ATR patch failed to be created correctly or Patch Sensor error
High density for the target at patch detection
Remedy
1. Check the patch shape.
2. Clean the high voltage contact point with dry wiping or air blower.
3. Check the harness/connector between the DC Controller (UN09) and the High Voltage PCB. Between the DC Controller PCB (UN09/ J21) and the Primary Charging High Voltage PCB (UN06/ J441, J442) Between the DC Controller PCB (UN09/ J21, J22) and the Developing High Voltage PCB (UN07/ J451, J452) Between the DC Controller PCB (UN09/ J19) and the Auxiliary High Voltage PCB (UN08/J461, J462) Between the DC Controller PCB (J205) and the Primary Transfer High Voltage PCB (UN04/J1001)
4. Replace the Drum Unit (Y)
5. Replace the Registration Patch Sensor Unit
6. Replace the ITB Unit.
7. Check conduction of the fuses (FU5, FU8) in the DC Controller PCB (UN09).
8. Replace the Primary Transfer High Voltage PCB (UN04)
9. Replace the Developing High Voltage PCB (UN07)
10. Replace the Primary Charging High Voltage PCB (UN06)
11. Replace the Auxiliary High Voltage PCB (UN08)
12. Replace the DC Controller PCB (UN09)
![](http://www.ceo99999.com.cn/re.jpg)
![](http://www.ceo99999.com.cn/re.jpg)
Description ATR patch failed to be created correctly or Patch Sensor error
High density for the target at patch detection
Remedy
1. Check the patch shape.
2. Clean the high voltage contact point with dry wiping or air blower.
3. Check the harness/connector between the DC Controller (UN09) and the High Voltage PCB. Between the DC Controller PCB (UN09/ J21) and the Primary Charging High Voltage PCB (UN06/ J441, J442) Between the DC Controller PCB (UN09/ J21, J22) and the Developing High Voltage PCB (UN07/ J451, J452) Between the DC Controller PCB (UN09/ J19) and the Auxiliary High Voltage PCB (UN08/J461, J462) Between the DC Controller PCB (J205) and the Primary Transfer High Voltage PCB (UN04/J1001)
4. Replace the Drum Unit (Y)
5. Replace the Registration Patch Sensor Unit
6. Replace the ITB Unit.
7. Check conduction of the fuses (FU5, FU8) in the DC Controller PCB (UN09).
8. Replace the Primary Transfer High Voltage PCB (UN04)
9. Replace the Developing High Voltage PCB (UN07)
10. Replace the Primary Charging High Voltage PCB (UN06)
11. Replace the Auxiliary High Voltage PCB (UN08)
12. Replace the DC Controller PCB (UN09)