佳能2002出現(xiàn)e003一0000代碼故障
更新時(shí)間:2024/11/18 9:37:16,view:408佳能打印機(jī)2002蘇州佳能打印機(jī)售后服務(wù)中心客服熱線69616769,蘇州佳能售后電話,佳能售后網(wǎng)點(diǎn), 佳能2002g定影膜清零操作流程, 佳能2002g進(jìn)入維修模式, 佳能2002G復(fù)印機(jī)E00-0000, 佳能2002g打印一半顏色淺,維修視頻
佳能2002報(bào)E0030000如何處理
主要原因 / 癥狀 異常低溫 ( 主熱敏電阻檢測 ) 在達(dá)到目標(biāo)溫度以后的初始旋 轉(zhuǎn)之中主熱敏電阻檢測的溫度 未達(dá)到目標(biāo)溫度。 對策 檢查定影薄膜單元的,更換定影部件
佳能IR2318L打印機(jī)經(jīng)常出現(xiàn)**0000030000錯(cuò)誤,需重啟。0002 E002 0000 E003 0000 E007 副熱敏電阻的讀數(shù)連續(xù)200msec為295℃以上。佳能2002出現(xiàn)e003一0000代碼故障 佳能2002售后技術(shù)論壇 UI 2018/10/10 16:30:52 看圖圖
佳能2002售后技術(shù)論壇 曹獗棍 2018/10/10 21:32:34 Code E003-0000
Description The main thermistor reading is lower than
140C when paper is moved
Causes The fixing film unit is faulty (i.e., the main thermistor (TH1) has poor contact or has an open circuit; or, the fixing heater is faulty). The main power supply PCB is faulty. The DC controller PCB is faulty. Caution To clear the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR.
Remedy
1. State Turn on the power switch, and clear E002/E003. Thereafter, turn off and then on the power switch. Does the fixing heater operate? NO: See “The fixing heater fails to operate.”
2. Wiring Is the wiring from the DC controller PCB to the fixing film unit normal? NO: Correct the wiring.
3. Fixing film unit, DC controller PCB Try replacing the fixing film unit. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.
佳能2002 316807847 2018/2/7 16:35:26 看不到提示
主要原因 / 癥狀 異常低溫 ( 主熱敏電阻檢測 ) 在達(dá)到目標(biāo)溫度以后的初始旋 轉(zhuǎn)之中主熱敏電阻檢測的溫度 未達(dá)到目標(biāo)溫度。 對策 檢查定影薄膜單元的,更換定影部件
佳能IR2318L打印機(jī)經(jīng)常出現(xiàn)**0000030000錯(cuò)誤,需重啟。0002 E002 0000 E003 0000 E007 副熱敏電阻的讀數(shù)連續(xù)200msec為295℃以上。佳能2002出現(xiàn)e003一0000代碼故障 佳能2002售后技術(shù)論壇 UI 2018/10/10 16:30:52 看圖圖
佳能2002售后技術(shù)論壇 曹獗棍 2018/10/10 21:32:34 Code E003-0000
Description The main thermistor reading is lower than
140C when paper is moved
Causes The fixing film unit is faulty (i.e., the main thermistor (TH1) has poor contact or has an open circuit; or, the fixing heater is faulty). The main power supply PCB is faulty. The DC controller PCB is faulty. Caution To clear the error, execute the following in service mode: COPIER>FUNCTION>CLEAR>ERR.
Remedy
1. State Turn on the power switch, and clear E002/E003. Thereafter, turn off and then on the power switch. Does the fixing heater operate? NO: See “The fixing heater fails to operate.”
2. Wiring Is the wiring from the DC controller PCB to the fixing film unit normal? NO: Correct the wiring.
3. Fixing film unit, DC controller PCB Try replacing the fixing film unit. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.
佳能2002 316807847 2018/2/7 16:35:26 看不到提示