hp LaserJet M725常見故障代碼描述,英文手冊4
更新時間:2024/9/17 1:36:55,view:128hp打印機HPLaserJetM725蘇州hp打印機售后服務(wù)中心客服熱線69616769,蘇州hp售后電話,hp售后網(wǎng)點,
Display:
50.WX.YZ Fuser error To continue turn off then on
Description:
W = 7, Fuser pressure-release mechanism failure
The product experienced a fuser error.
• W = fuser error code
• X = fuser mode
- 0: Photo paper 1, 2, 3, Designated paper 2, 3, or NA, typed or Auto-sense - 1: Auto sense (Normal special case distinguished from typed Normal) - 2: Normal, typed (not Auto sense) - 3: Light paper 1, 2, or 3, typed or Auto sense - 4: Heavy paper 1, typed or Auto sense - 5: Heavy paper 2, typed or Auto sense - 6: Heavy paper 3, typed or Auto sense - 7: Glossy paper 1, typed or Auto sense - 8: Glossy paper 2, typed or Auto sense - 9: Glossy paper 3, typed or Auto sense - A: Glossy film, typed or Auto sense - B: Transparency, typed or Auto sense - C: Label - D: Envelope1, Envelope2, or Envelope3 - E: Rough (designated paper 1), typed or Auto sense - F: Reserved for future fuser mode
• Y = previous product sleep state
• Z = next product sleep state
- 0: Printing - 1: Standby level 1 (no temperature control) - 2: Standby level 2 (high temperature control) - 3: Standby level 3 (middle temperature control) - 4: Standby level 4 (low temperature control) - 5: Middle sleep - 6: Deep sleep - F: Off
Remedy:
1. Remove and then reseat the fuser. Make sure there is no residual paper in the fuser. 2. Check the fuser pressure-release sensor flag. If it is damaged, replace the fuser. 3. Use the fuser pressure-release drive test in the component test to verify that the fuser motor (M3) is properly functioning. If it is not, replace the fuser motor (M3). 4. If this product was previously serviced, check the connector (J61) on the DC controller PCA. 5. If the error persists, replace the fuser.
Code: 50.8X.YZ
Display:
50.WX.YZ Fuser error To continue turn off then on
Description:
W = 8, Low fuser temperature 2
The product experienced a fuser error.
• W = fuser error code
• X = fuser mode
- 0: Photo paper 1, 2, 3, Designated paper 2, 3, or NA, typed or Auto-sense - 1: Auto sense (Normal special case distinguished from typed Normal) - 2: Normal, typed (not Auto sense) - 3: Light paper 1, 2, or 3, typed or Auto sense - 4: Heavy paper 1, typed or Auto sense - 5: Heavy paper 2, typed or Auto sense - 6: Heavy paper 3, typed or Auto sense - 7: Glossy paper 1, typed or Auto sense - 8: Glossy paper 2, typed or Auto sense - 9: Glossy paper 3, typed or Auto sense - A: Glossy film, typed or Auto sense - B: Transparency, typed or Auto sense - C: Label - D: Envelope1, Envelope2, or Envelope3 - E: Rough (designated paper 1), typed or Auto sense - F: Reserved for future fuser mode
• Y = previous product sleep state
• Z = next product sleep state
- 0: Printing - 1: Standby level 1 (no temperature control) - 2: Standby level 2 (high temperature control) - 3: Standby level 3 (middle temperature control) - 4: Standby level 4 (low temperature control) - 5: Middle sleep - 6: Deep sleep - F: Off
Remedy:
1. Remove and then reseat the fuser. Make sure there is no residual paper in the fuser. Make sure the product is not located in front of a vent or window where cool air may interfere with the ability of the fuser to heat up. 2. Check the product power source. Make sure the power source meets product requirements. Make sure this is the only device using the circuit. 3. Check the connector (J1) between the fuser and the product. If it is damaged, replace the fuser. 4. If this product was previously serviced, check the connector (J61) on the DC controller PCA. 5. If the error persists, replace the fuser.
Code: 50.9X.YZ
Display:
50.WX.YZ Fuser error To continue turn off then on
Description:
W = 9, High fuser temperature 2
The product experienced a fuser error.
• W = fuser error code
• X = fuser mode
- 0: Photo paper 1, 2, 3, Designated paper 2, 3, or NA, typed or Auto-sense - 1: Auto sense (Normal special case distinguished from typed Normal) - 2: Normal, typed (not Auto sense) - 3: Light paper 1, 2, or 3, typed or Auto sense - 4: Heavy paper 1, typed or Auto sense - 5: Heavy paper 2, typed or Auto sense - 6: Heavy paper 3, typed or Auto sense - 7: Glossy paper 1, typed or Auto sense - 8: Glossy paper 2, typed or Auto sense - 9: Glossy paper 3, typed or Auto sense - A: Glossy film, typed or Auto sense - B: Transparency, typed or Auto sense - C: Label - D: Envelope1, Envelope2, or Envelope3 - E: Rough (designated paper 1), typed or Auto sense - F: Reserved for future fuser mode
• Y = previous product sleep state
• Z = next product sleep state
- 0: Printing - 1: Standby level 1 (no temperature control) - 2: Standby level 2 (high temperature control) - 3: Standby level 3 (middle temperature control) - 4: Standby level 4 (low temperature control) - 5: Middle sleep - 6: Deep sleep - F: Off
Remedy:
1. Remove and then reseat the fuser. Make sure there is no residual paper in the fuser. Make sure the product is not located in front of a vent or window where cool air may interfere with the ability of the fuser to heat up. 2. Check the product power source. Make sure the power source meets product requirements. Make sure this is the only device using the circuit. 3. Check the connector (J1) between the fuser and the product. If it is damaged, replace the fuser. 4. If this product was previously serviced, check the connector (J61) on the DC controller PCA. 5. If the error persists, replace the fuser.
Code: 50.AX.YZ
Display:
50.WX.YZ Fuser error To continue turn off then on
Description:
W = A: High fuser temperature 2
The product experienced a fuser error.
• W = fuser error code
• X = fuser mode
- 0: Photo paper 1, 2, 3, Designated paper 2, 3, or NA, typed or Auto-sense - 1: Auto sense (Normal special case distinguished from typed Normal) - 2: Normal, typed (not Auto sense) - 3: Light paper 1, 2, or 3, typed or Auto sense - 4: Heavy paper 1, typed or Auto sense - 5: Heavy paper 2, typed or Auto sense - 6: Heavy paper 3, typed or Auto sense - 7: Glossy paper 1, typed or Auto sense - 8: Glossy paper 2, typed or Auto sense - 9: Glossy paper 3, typed or Auto sense - A: Glossy film, typed or Auto sense - B: Transparency, typed or Auto sense - C: Label - D: Envelope1, Envelope2, or Envelope3 - E: Rough (designated paper 1), typed or Auto sense - F: Reserved for future fuser mode
• Y = previous product sleep state
• Z = next product sleep state
- 0: Printing - 1: Standby level 1 (no temperature control) - 2: Standby level 2 (high temperature control) - 3: Standby level 3 (middle temperature control) - 4: Standby level 4 (low temperature control) - 5: Middle sleep - 6: Deep sleep - F: Off
Remedy:
1. Remove and then reseat the fuser. Make sure there is no residual paper in the fuser. Make sure the product is not located in front of a vent or window where cool air may interfere with the ability of the fuser to heat up. 2. Check the product power source. Make sure the power source meets product requirements. Make sure this is the only device using the circuit. 3. Check the connector (J1) between the fuser and the product. If it is damaged, replace the fuser. 4. If this product was previously serviced, check the connector (J61) on the DC controller PCA. 5. If the error persists, replace the fuser.
Code: 50.BX.YZ
Display:
50.WX.YZ Fuser error To continue turn off then on
Description:
W = B: High fuser temperature 3
The product experienced a fuser error.
• W = fuser error code
• X = fuser mode
- 0: Photo paper 1, 2, 3, Designated paper 2, 3, or NA, typed or Auto-sense - 1: Auto sense (Normal special case distinguished from typed Normal) - 2: Normal, typed (not Auto sense) - 3: Light paper 1, 2, or 3, typed or Auto sense - 4: Heavy paper 1, typed or Auto sense - 5: Heavy paper 2, typed or Auto sense - 6: Heavy paper 3, typed or Auto sense - 7: Glossy paper 1, typed or Auto sense - 8: Glossy paper 2, typed or Auto sense - 9: Glossy paper 3, typed or Auto sense - A: Glossy film, typed or Auto sense - B: Transparency, typed or Auto sense - C: Label - D: Envelope1, Envelope2, or Envelope3 - E: Rough (designated paper 1), typed or Auto sense - F: Reserved for future fuser mode
• Y = previous product sleep state
• Z = next product sleep state
- 0: Printing - 1: Standby level 1 (no temperature control) - 2: Standby level 2 (high temperature control) - 3: Standby level 3 (middle temperature control) - 4: Standby level 4 (low temperature control) - 5: Middle sleep - 6: Deep sleep - F: Off
Remedy:
1. Remove and then reseat the fuser. Remove any residual paper in the product. 2. Check the paper type setting using the product menus and in the print driver. Making sure that they match and are correct for the type of paper being used. 3. If this product was previously serviced, check the connector (J61) on the DC controller PCA. 4. If the error persists, replace the fuser.
Code: 51.00.10
Display:
51.00.YY Error To continue turn off then on
Description:
An error with the laser scanner assembly has occurred in the product.
Beam detect error
Remedy:
1. Turn the product off and then on. 2. Check the flat flexible cable (FFC) connection to the laser scanner. 3. Check connector J71 at the DC controller, and check the laser scanner connectors. 4. Replace the laser scanner.
Code: 51.00.19
Display:
51.00.YY Error To continue turn off then on
Description:
An error with the laser scanner assembly has occurred in the product.
Laser malfunction
Remedy:
1. Turn the product off and then on. 2. Check the connectors on the laser scanner. 3. Replace the laser scanner.
Code: 51.00.20
Display:
51.00.YY Error To continue turn off then on
Description:
An error with the laser scanner assembly has occurred in the product.
Black laser scanner error
Remedy:
1. Perform the laser scanner component tests in the Troubleshooting menu. Verify that you can hear the motor rotate. 2. If you cannot hear the motor rotate, verify that connector J71 is fully seated on the DC controller PCA. 3. Verify that the connector on the laser scanner assembly is securely attached. 4. If the error persists, replace the laser scanner.
Code: 52.00.00
Display:
52.00.00 Error To continue turn off then on
Description:
A scanner rotation error has occurred.
Remedy:
1. Turn the product off and then on. 2. Perform the laser scanner component tests in the Troubleshooting menu. 3. If the component tests showed a failure, reconnect the connectors of the scanner motor (J1900 and J801) and the DC controller PCA (J71). 4. Replace the laser-scanner assembly.
Code: 52.00.20
Display:
52.00.20 Error To continue turn off then on
Description:
A scanner rotation error has occurred.
Remedy:
1. Turn the product off and then on. 2. Perform the laser scanner component tests in the Troubleshooting menu. 3. If the component tests showed a startup failure, reconnect the connectors of the scanner motor (J1900 and J801) and the DC controller PCA (J71). 4. Replace the laser-scanner assembly.
Code: 52.04.00
Display:
52.
Description:
The laser scanner experienced a startup error.
Laser scanner motor startup error
Remedy:
1. Perform the laser scanner component tests in the Troubleshooting menu. 2. Check the connectors (J1900 and J801) on the laser scanner driver PCA and the connector (J71) on the DC controller PCA. 3. If the error persists, replace the laser scanner.
Code: 52.05.00
Display:
52.
Description:
The laser scanner experienced a startup error.
Laser scanner rotation error
Remedy:
1. Perform the laser scanner component tests in the Troubleshooting menu. 2. Check the connectors (J1900 and J801) on the laser scanner driver PCA and the connector (J71) on the DC controller PCA. 3. If the error persists, replace the laser scanner.
Code: 54.00.03
Display:
54.XX.YY Error
Description:
A sensor error has occurred.
Environmental sensor failure
Remedy:
1. Turn the product off and then on. 2. If the environment sensor has been removed or replaced. check the connector on the environment sensor and the connector (J63) on the DC controller PCA. 3. If the error persists, replace the environment sensor assembly.
Code: 54.00.04
Display:
54.XX.YY Error
Description:
A sensor error has occurred.
Engine temperature sensor 1 abnormality warning
Remedy:
1. Turn the product off and then on.
Code: 55.XX.YY
Display:
55.XX.YY DC controller error To continue turn off then on
Description:
The communication link between the formatter and DC controller was lost. • 55.00.00 (event code): Internal communication error • 55.00.01 (event code): DC controller memory error • 55.00.03 (event code): DC controller no engine response • 55.00.04 (event code): DC controller communications time-out
Remedy:
1. Turn the product off and then on. 2. Perform an engine test. 3. Verify the connectors on the DC controller. 4. If the error persists, replace the DC controller.
Code: 56.00.YY
Display:
56.00.YY Error To continue turn off then on
Description:
The product experienced a communication error with the optional paper tray. • 56.00.01 (event code): Illegal input, selected paper input tray is unavailable • 56.00.02 (event code): Illegal output, selected paper output bin is unavailable
Remedy:
1. Turn the product off and then on. 2. Reseat the optional paper tray. 3. Check the input connectors for damage. If a connector is damaged, replace the connector. 4. Remove any third-party hardware. 5. Upgrade the firmware. 6. If the error persists, replace the DC controller.
Code: 57.00.01
Display:
57.00.0X Error
Description:
A fan error has occurred.
Fan motor 1 (rear) malfunction
Remedy:
1. Turn the product off and then on. Listen for fan noise at the rear of the product. If no noise is heard, replace the power supply fan (FM1). 2. If this part has been removed or replaced, check the connector (J33) on the DC controller PCA.
熱門圖文