Sharp MXM1055常見故障代碼描述,英文手冊(cè)2
更新時(shí)間:2024/11/22 9:04:39,view:195sharp打印機(jī)SharpMXM1055蘇州sharp打印機(jī)售后服務(wù)中心客服熱線69616769,蘇州sharp售后電話,sharp售后網(wǎng)點(diǎn),
Description:
Finisher paper alignment roller lift motor section abnormality (FNM112)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the paper alignment roller lift motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-29
Description:
Finisher PWB cooling fan abnormality (FNFAN102)
Causes:
Motor lock, motor harness short/open, control PWB trouble, disconnection of harness or connector.
Remedy:
Use SIM3-3 to check the operation of the control PWB cooling fan. Check connection from the control PWB to the motor. Replace the control PWB and the fan motor.
Code: F0-30
Description:
Communication trouble between the finisher and the saddle
Causes:
Noise on the communication line, control PWB trouble, disconnection of connector or harness.
Remedy:
Turn OFF/ON the power. Check the connector between the finisher and the saddle. Replace the control PWB of the saddle unit.
Code: F0-31
Description:
Finisher saddle folding motor section abnormality (FSM206)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the saddle paper folding motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-32
Description:
Finisher relay unit transport motor section abnormality (PIM301)
Causes:
Motor lock, motor harness short/open, control PWB trouble, disconnection of harness or connector.
Remedy:
Use SIM3-3 to check the operation of the relay paper transport motor. Check connection from the control PWB to the motor. Turn OFF/ON the power. Replace the control PWB and the motor.
Code: F0-33
Description:
Finisher punch shift motor section abnormality (FNM113)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the punch shift motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-34
Description:
Finisher punch motor section abnormality (FNM117)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the punch motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-37
Description:
Finisher backup RAM trouble
Causes:
Finisher control PWB trouble, EEPROM chip breakdown.
Remedy:
Replace the finisher control PWB.
Code: F0-40
Description:
Communication trouble between the finisher saddle and the trimmer
Causes:
Noise on the communication line, control PWB trouble, disconnection of connector or harness.
Remedy:
Turn OFF/ON the power. Check the connector between the saddle and the trimmer unit. Replace the control PWB of the saddle unit. Replace the control PWB of the trimmer unit.
Code: F0-41
Description:
Finisher saddle lead edge stopper motor section abnormality (FSM203)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the saddle lead edge stopper motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-42
Description:
Finisher saddle folding roller guide motor section abnormality (FSM204)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the saddle folding roller guide motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-43
Description:
Finisher saddle alignment motor section abnormality (FSM212)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the saddle paper alignment motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-44
Description:
Finisher saddle rear edge hold motor section abnormality (FSM210)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the saddle rear edge hold motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-45
Description:
Finisher saddle staple motor section abnormality (FSM209)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the saddle staple motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-46
Description:
Finisher saddle rear edge shift motor section abnormality (FSM211)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the saddle rear edge shift motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-47
Description:
Finisher saddle flap motor section abnormality (FSM213)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the saddle flap motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-48
Description:
Finisher saddle push motor section abnormality (FSM205)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the saddle push motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-49
Description:
Finisher saddle separation motor section abnormality (FSM214)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the saddle separation motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-51
Description:
Finisher trimmer cutter motor abnormality (FTM106)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the trimmer cutter motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-52
Description:
Finisher trimmer registration motor section abnormality (FTM102)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the trimmer registration motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-53
Description:
Finisher trimmer inlet port separation motor abnormality (FTM103)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the trimmer inlet port separation motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-54
Description:
Finisher trimmer paper exit separation motor section abnormality (FTM104)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the trimmer paper exit separation motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-55
Description:
Finisher trimmer bundle press motor section abnormality (FTM105)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the trimmer bundle press motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-56
Description:
Paper remaining trouble in the finisher trimmer
Causes:
Trimmer inlet port sensor breakdown The paper bundle is bent and cannot be transported.
Remedy:
Use SIM3-3 to check the operation of the trimmer transport motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part. Check the paper bundle can be transported or not.
Code: F0-60
Description:
Communication trouble between the stacker first series and the downstream units.
Causes:
Communication trouble with the stacker and the downstream unit of the stacker Stacker unit ID setting failure (Setting failure of the DIP switch on the control PWB), noises on the communication line, control PWB trouble, connector connection failure, harness breakage, disconnection of an AC cable to a downstream unit
Remedy:
Turn OFF/ON the power. Check connection between the stacker and the downstream unit of the stacker. Replace the control PWB of the downstream unit of the stacker.
Code: F0-61
Description:
Stacker first series offset unit abnormality
Causes:
Abnormal operation of the offset motor which shifts the stack tray paper exit roller Offset home sensor detection trouble Control PWB trouble, disconnection of connector trouble, motor trouble, sensor trouble
Remedy:
Use SIM03-61 to check the operation of the offset motor. Use SIM03-60 to check the offset home sensor signal. Replace the control PWB. Check connection of the connector and harness from the control PWB to the offset motor. Check connection of the connector and harness from the control PWB to the offset home sensor.
Code: F0-62
Description:
Stacker first series front side jogger abnormality
Causes:
Abnormal operation of the front side jogger motor for driving the alignment plate (front side) Alignment plate (front side) home position front side jogger home sensor detection trouble Control PWB trouble, disconnection of connector trouble, motor trouble, sensor trouble
Remedy:
Use SIM03-61 to check the operation of the front side jogger motor. Use SIM03-60 to check the front side jogger home sensor signal. Replace the control PWB. Check connection of the connector and harness from the control PWB to the front side jogger motor. Check connection of the connector and harness from the control PWB to the front side jogger home sensor.
Code: F0-63
Description:
Stacker first series rear side jogger abnormality
Causes:
Abnormal operation of the rear side jogger motor for driving the alignment plate (rear side) Alignment plate (rear side) home position rear side jogger home sensor detection trouble Control PWB trouble, disconnection of connector trouble, motor trouble, sensor trouble
Remedy:
Use SIM03-61 to check the operation of the rear side jogger motor. Use SIM03-60 to check the rear side jogger home sensor signal. Replace the control PWB. Check connection of the connector and harness from the control PWB to the rear side jogger motor. Check connection of the connector and harness from the control PWB to the rear side jogger home sensor.
Code: F0-64
Description:
Stacker first series lead edge jogger abnormality
Causes:
Abnormal operation of the lead edge jogger motor for driving the alignment plate (lead edge) Alignment plate (lead edge) home position lead edge jogger home sensor detection trouble Control PWB trouble, disconnection of connector trouble, motor trouble, sensor trouble
Remedy:
Use SIM03-61 to check the operation of the lead edge jogger motor. Use SIM03-60 to check the lead edge jogger home sensor signal. Replace the control PWB. Check connection of the connector and harness from the control PWB to the lead edge jogger motor. Check connection of the connector and harness from the control PWB to the lead edge jogger home sensor.
Code: F0-65
Description:
Stacker first series stack tray abnormality
Causes:
Abnormal operation of the stack tray lift motor Abnormality of the tray DC motor encoder sensor for detecting the motor rotation Tray limit switch (upper limit, lower limit) operation Stack tray home sensor abnormality, stack tray 25% load position sensor abnormality, stack tray 50% load position sensor abnormality, stack tray 75% load position sensor abnormality, stack tray 100% load position sensor abnormality, stack tray extendable position sensor abnormality Control PWB trouble, disconnection of connector trouble, motor trouble, sensor trouble.
Remedy:
Use SIM03-61 to check the operation of the stack tray lift motor. Use SIM03-60 to check the tray DC motor encoder sensor signal. Use SIM03-60 to check the operation of the tray limit switch (upper limit, lower limit). Use SIM03-60 to check each tray position sensor signal and to check that two or more sensors are not simultaneously ON. Replace the control PWB. Check connection of the connector and harness from the control PWB to the stack tray lift motor. Check connection of the connector and harness from the control PWB to the tray DC motor encoder sensor. Check connection of the connector and harness from the control PWB to the tray limit switch (upper limit, lower limit). Check connection of the connector and harness from the control PWB to each tray position sensor.
Code: F0-70
Description:
Communication trouble between the finisher and the folding unit
Causes:
Noise on the communication line, control PWB trouble, disconnection of connector or harness.
Remedy:
Turn OFF/ON the power. Check connection between the finisher and the folding unit. Replace the control PWB of the folding unit.
Code: F0-71
Description:
Folding unit lead edge holding guide motor section abnormality (FLM10)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the folding unit lead edge holding guide motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-72
Description:
Folding unit backup RAM trouble
Causes:
Folding unit control PWB trouble, EEPROM chip breakdown
Remedy:
Replace the folding unit control PWB.
Code: F0-73
Description:
Folding unit power fan abnormality
Causes:
Motor lock, motor harness short/open, control PWB trouble, disconnection of harness or connector.
Remedy:
Check connection from the control PWB to the fan motor. Replace the control PWB. Replace the fan motor.
Code: F0-74
Description:
Folding unit folding tray paper exit motor section abnormality (FLM14)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown
Remedy:
Use SIM3-3 to check the operation of the folding unit folding tray paper exit motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-75
Description:
Folding unit upper stopper motor section abnormality (FLM8)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the folding unit upper stopper motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-76
Description:
3-fold stopper motor section in the folding unit is abnormal (FLM9)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-41 to check the operation of the 3-fold stopper motor in the folding unit. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-77
Description:
Folding unit transport motor section abnormality (FLM11)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector.
Remedy:
Use SIM3-41 to check the operation of the folding unit transport motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor.
Code: F0-80
Description:
Finisher power cooling fan motor abnormality (FNFAN101)
Causes:
Motor lock, motor harness short/open, control PWB trouble, disconnection of harness or connector.
Remedy:
Check connection from the control PWB to the fan motor. Replace the control PWB. Replace the fan motor.
Code: F0-81
Description:
Finisher upper tray fan abnormality (FNFAN103)
Causes:
Motor lock, motor harness short/open, control PWB trouble, disconnection of harness or connector.
Remedy:
Use SIM3-3 to check the operation of the upper tray fan. Check connection from the control PWB to the fan motor. Replace the control PWB. Replace the fan motor.
Code: F0-82
Description:
Finisher lower tray fan abnormality (FNFAN104)
Causes:
Motor lock, motor harness short/open, control PWB trouble, disconnection of harness or connector.
Remedy:
Use SIM3-3 to check the operation of the lower tray fan. Check connection from the control PWB to the fan motor. Replace the control PWB. Replace the fan motor.
Code: F0-83
Description:
Finisher paper guide motor section abnormality (FNM120)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the paper guide motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-84
Description:
Finisher grip section abnormality (FNM116)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown.
Remedy:
Use SIM3-3 to check the operation of the gripper motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-86
Description:
Finisher discharged paper hold motor section abnormality (FNM118)
Causes:
Motor lock, control PWB trouble, disconnection of harness or connector, hp sensor breakdown
Remedy:
Use SIM3-3 to check the operation of the discharged paper hold motor. Check connection from the control PWB to the motor and the sensor. Replace the control PWB, the motor, and the sensor part.
Code: F0-90
Description:
Communication trouble between the stacker second series and the downstream units.
Causes:
Communication trouble with the stacker and the downstream unit of the stacker Stacker unit ID setting failure (Setting failure of the DIP switch on the control PWB), noises on the communication line, control PWB trouble, connector connection failure, harness breakage, disconnection of an AC cable to a downstream unit
Remedy:
Turn OFF/ON the power. Check connection between the stacker and the downstream unit of the stacker. Replace the control PWB of the downstream unit of the stacker.
Code: F0-91
Description:
Stacker second series offset unit abnormality
Causes:
Abnormal operation of the offset motor which shifts the stack tray paper exit roller Offset home sensor detection trouble Control PWB trouble, disconnection of connector trouble, motor trouble, sensor trouble
Remedy:
Use SIM03-61 to check the operation of the offset motor. Use SIM03-60 to check the offset home sensor signal. Replace the control PWB. Check connection of the connector and harness from the control PWB to the offset motor. Check connection of the connector and harness from the control PWB to the offset home sensor.
Code: F0-92
Description:
Stacker second series front side jogger abnormality
Causes:
Abnormal operation of the front side jogger motor for driving the alignment plate (front side) Alignment plate (front side) home position front side jogger home sensor detection trouble Control PWB trouble, disconnection of connector trouble, motor trouble, sensor trouble
Remedy:
Use SIM03-61 to check the operation of the front side jogger motor. Use SIM03-60 to check the front side jogger home sensor signal. Replace the control PWB. Check connection of the connector and harness from the control PWB to the front side jogger motor. Check connection of the connector and harness from the control PWB to the front side jogger home sensor.
Code: F0-93
Description:
Stacker second series rear side jogger abnormality
Causes:
Abnormal operation of the rear side jogger motor for driving the alignment plate (rear side) Alignment plate (rear side) home position rear side jogger home sensor detection trouble Control PWB trouble, disconnection of connector trouble, motor trouble, sensor trouble
Remedy:
Use SIM03-61 to check the operation of the rear side jogger motor. Use SIM03-60 to check the rear side jogger home sensor signal. Replace the control PWB. Check connection of the connector and harness from the control PWB to the rear side jogger motor. Check connection of the connector and harness from the control PWB to the rear side jogger home sensor.
Code: F0-94
Description:
Stacker second series lead edge jogger abnormality
Causes:
Abnormal operation of the lead edge jogger motor for driving the alignment plate (lead edge) Alignment plate (lead edge) home position lead edge jogger home sensor detection trouble Control PWB trouble, disconnection of connector trouble, motor trouble, sensor trouble
Remedy:
Use SIM03-61 to check the operation of the lead edge jogger motor. Use SIM03-60 to check the lead edge jogger home sensor signal. Replace the control PWB. Check connection of the connector and harness from the control PWB to the lead edge jogger motor. Check connection of the connector and harness from the control PWB to the lead edge jogger home sensor.
Code: F0-95
Description:
Stacker second series stack tray abnormality
Causes:
Abnormal operation of the stack tray lift motor Abnormality of the tray DC motor encoder sensor for detecting the motor rotation Tray limit switch (upper limit, lower limit) operation Stack tray home sensor abnormality, stack tray 25% load position sensor abnormality, stack tray 50% load position sensor abnormality, stack tray 75% load position sensor abnormality, stack tray 100% load position sensor abnormality, stack tray extendable position sensor abnormality Control PWB trouble, disconnection of connector trouble, motor trouble, sensor trouble
Remedy:
Use SIM03-61 to check the operation of the stack tray lift motor. Use SIM03-60 to check the tray DC motor encoder sensor signal. Use SIM03-60 to check the operation of the tray limit switch (upper limit, lower limit). Use SIM03-60 to check each tray position sensor signal and to check that two or more sensors are not simultaneously ON. Replace the control PWB. Check connection of the connector and harness from the control PWB to the stack tray lift motor. Check connection of the connector and harness from the control PWB to the tray DC motor encoder sensor. Check connection of the connector and harness from the control PWB to the tray limit switch (upper limit, lower limit). Check connection of the connector and harness from the control PWB to each tray position sensor.
Code: F1-00
Description:
Finisher - PCU PWB communication error
Causes:
Connection trouble of the connector and the harness between the finisher and the PCU PWB. Finisher control PWB trouble. PCU PWB trouble.
Remedy:
Check the connector and the harness between the finisher and the PCU PWB. Replace the finisher control PWB. Replace the PCU PWB.
Code: F1-01
Description:
Jogger motor trouble
Causes:
Motor lock, control PWB trouble, home position sensor breakdown, connection harness / connector connection trouble
Remedy:
Use Sim. 3-3 to check the operation of the jogger motor. Check connection from the control PWB to the motor. Replace the control PWB and the sensor part.
Code: F1-08
Description:
Stapler shift trouble (FSM)
Causes:
Stapler shift motor trouble. Finisher control PWB trouble. Home position sensor trouble.
Remedy:
Use SIM3-3 to check the operation of the stapler shift motor. Use SIM3-2 to check the operation of the home position sensor. Replace the stapler shift motor. Check connection of the connector and the harness. Replace the home position sensor. Replace the finisher control PWB.
Code: F1-09
Description:
Staple diagonal motor trouble
Causes:
Motor lock, motor harness short/open, control PWB trouble, home position sensor trouble, connection harness / connector connection trouble
Remedy:
Use Sim. 3-3 to check the operation of the stapler diagonal motor. Check connection from the control PWB to the motor. Replace the control PWB and the sensor part.
Code: F1-10
Description:
Staple operation trouble (FFSM)
Causes:
Staple motor trouble. Finisher control PWB trouble. Home position sensor trouble.
Remedy:
Use SIM3-3 to check the operation of the staple motor. Use SIM3-2 to check the operation of the home position sensor. Replace the staple motor. Check connection of the connector and the harness. Replace the home position sensor. Replace the finisher control PWB.
Code: F1-11
Description:
Finisher bundle exit motor trouble
Causes:
Motor lock, motor harness short/open, control PWB trouble, home position sensor trouble, connection harness / connector connection trouble
Remedy:
Use Sim. 3-3 to check the operation of the discharge motor. Check connection from the control PWB to the motor. Replace the control PWB and the sensor part.
Code: F1-13
Description:
Paper exit guide plate open /close motor trouble
Causes:
Motor lock, motor harness short / open, control PWB trouble, home position sensor trouble, connection harness/connector connection trouble.
Remedy:
Use Sim. 3-3 to check the operation of the paper exit port open/close motor. Check connection from the control PWB to the motor. Replace the control PWB and the sensor part.
Code: F1-15
Description:
Finisher paper exit tray lift operation trouble (FTLM)
Causes:
Paper exit tray lift motor trouble. Finisher control PWB trouble. Home position sensor trouble.
Remedy:
Use SIM3-3 to check the operation of the paper exit tray lift motor. Use SIM3-2 to check the operation of the home position sensor. Replace the finisher control PWB. Replace the paper exit tray lift motor. Replace the home position sensor.
Code: F1-23
Description:
Bundle branch open/close motor trouble
Causes:
Motor lock trouble. Control PWB trouble. Home position sensor trouble. Connection harness/connector connection trouble.
Remedy:
Check the operation of the bundle paper exit motor with SIM3-3. Check connection from the control PWB to the motor. Replace the control PWB.
Code: F1-31
Description:
Finisher saddle motor trouble (Saddle stitch finisher) (FSFOM)
Causes:
Saddle paper folding motor trouble. Saddle paper folding mechanism trouble. Finisher control PWB trouble. Folding plate home position sensor trouble. Saddle paper folding motor rotation sensor trouble. Harness/connector connection trouble. PCU PWB trouble.
Remedy:
Use SIM3-3 to check the operation of the saddle motor. Check the saddle paper folding mechanism. Check the finisher control PWB, and replace if necessary. Check the folding plate home position sensor, and replace if necessary. Check the saddle paper folding motor rotation sensor, and replace if necessary. Check connection of the harness/connector, and replace if necessary. Check the PCU PWB, and replace if necessary.
Code: F1-33
Description:
Punch unit shift operation trouble (FPSM)
Causes:
Punch shift motor trouble. Finisher control PWB trouble. Home position sensor trouble. Harness and connector connection trouble.
Remedy:
Use SIM3-3 to check the operation of the punch shifting. Use SIM3-2 to check the operation of the home position sensor. Replace the punch shift motor. Replace the finisher control PWB. Replace the home position sensor. Check connection of the connectors and the harness.
Code: F1-34
Description:
Punch operation trouble (FPNM)
Causes:
Punch motor trouble. Finisher control PWB trouble. Home position sensor trouble. Harness and connector connection trouble
Remedy:
Use SIM3-2 to check the operation of the home position sensor. Use SIM3-3 to check the operation of the punch. Replace the punch motor. Replace the finisher control PWB. Replace the home position sensor. Check connection of the connectors and the harness.
Code: F1-35
Description:
Horizontal registration detection motor trouble
Causes:
Motor lock, motor harness short / open, control PWB trouble, home position sensor trouble, connection harness / connector connection trouble.
Remedy:
Use Sim. 3-3 to check the operation of the horizontal resist detection motor. Check connection from the control PWB to the motor. Replace the control PWB and the sensor part.
Code: F1-44
Description:
Staple motor 3 trouble
Causes:
Saddle staple motor R trouble. Finisher control PWB trouble. Home position sensor trouble. Harness and connector connection trouble
Remedy:
Use SIM3-3 to check the operation of the saddle staple motor R. Check connection from the control PWB to the motor. Turn OFF/ON the power. Replace the control PWB. Replace the sensor.
Code: F1-45
Description:
Saddle staple trouble (FSFSTM)
Causes:
Saddle staple motor trouble. Finisher control PWB trouble. Home position sensor trouble. Harness and connector connection trouble.
Remedy:
Use SIM3-3 to check the operation of the saddle staple motor. Check connection from the control PWB to the motor. Turn OFF/ON the power. Replace the control PWB. Replace the sensor.
Code: F1-46
Description:
Rear edge fence motor trouble
Causes:
Saddle motor trouble. Finisher control PWB trouble. Home position sensor trouble. Harness and connector connection trouble.
Remedy:
Use SIM3-3 to check the operation of the saddle motor. Check connection from the control PWB to the motor. Turn OFF/ON the power. Replace the control PWB. Replace the sensor.
Code: F1-47
Description:
Drive collar oscillation motor trouble
Causes:
Motor lock, control PWB trouble, home position sensor breakdown, connection harness / connector connection trouble.
Remedy:
Use Sim. 3-3 and Sim. 3-1 to check the operation of the jogger motor. Check connection from the control PWB to the motor. Replace the control PWB and the sensor part.
Code: F1-48
Description:
Saddle discharge motor trouble
Causes:
Motor lock, control PWB trouble, home position sensor breakdown, connection harness / connector connection trouble.
Remedy:
Use Sim. 3-1 to check the operation of the saddle discharge motor. Check connection from the control PWB to the motor, and turn OFF /ON the power. Replace the control PWB and the sensor part.
Code: F1-50
Description:
Main unit - Finisher combination error
Causes:
The finisher which is not supported by the main unit model is installed. Finisher control PWB trouble
Remedy:
Install a proper finisher. Replace the finisher control PWB.
Code: F1-60
Description:
Communication trouble between peripheral devices (Inserter detection)
Causes:
Noise on the communication line Control PWB trouble. Harness and connector connection trouble.
Remedy:
Turn OFF/ON the power. Check connection of the connector with the downstream units of the inserter. Replace the control PWB of the downstream units of the inserter.