Code: U2-90
Description:
EEPROM read / write error (PCU detection)
Causes:
EEPROM trouble. Installation of non-initialized EEPROM. PCU PWB EEPROM access circuit trouble.
Remedy:
Check that the EEPROM is properly set. To keep the counter data and the adjustment values, use the simulation to save the counter data and the adjustment values. (When there is a printer option, execute Sim. 22-1 to save the counter data and the adjustment values.) Replace the PCU PWB. Use Sim. 16 to cancel the trouble.
Code: U2-91
Description:
EEPROM check sum error (PCU detection)
Causes:
EEPROM trouble. Control circuit malfunction due to noises. PCU PWB EEPROM access circuit trouble.
Remedy:
Check that the EEPROM is properly set. To keep the counter data and the adjustment values, use the simulation to save the counter data and the adjustment values. (When there is a printer option, execute Sim. 22-1 to save the counter data and the adjustment values.) Replace the PCU PWB. Use Sim. 16 to cancel the trouble.
Code: U5-00
Description:
SPF communication trouble. SCU-DSPF communication error. Communication line test error when turning on the power or after canceling the exclusive simulation.
Causes:
Connector and harness contact trouble or disconnection. Control PWB (SCU) trouble or DSPF PWB trouble. Malfunction due to noises.
Remedy:
Turn OFF /ON the power to cancel. Check the connector and the harness of the communication line. Replace the SCU PWB or replace the DSPF PWB.
Code: U5-11
Description:
DSPF random pick motor trouble (DSPF detection). Random pick motor trouble (SPURUD is not changed within the specified time) is detected
Causes:
Random pick unit trouble
Remedy:
Check the STLD and the harness and the connector. Check the random pick-up motor and the related circuits (DSPFcnt, DSPF-Driver).
Code: U5-16
Description:
SPF fan motor trouble. The lock signal is detected during rotation of the fan / The non-lock state is detected when the motor is not rotated in booting
Causes:
Fan motor trouble. Trouble in the harness related to the fan. Circuit trouble.
Remedy:
Use Sim. 2-3 to check the operation. Check the fan motor related circuits (DSPFcnt, DSPFDriver) and their harness and connector.
Code: U5-30
Description:
SPF tray lift-up trouble. The lift-up trouble (STUD is not turned ON within the specified time) is detected 5 times continuously. When lifting again, a trouble occurs from the first time.
Causes:
STUD/ STLD trouble
Remedy:
Check the STUD/ STLD and their harness and the connector. Check the lift-up related circuit (DSPFcnt, DSPF-Driver). Check the lift-up unit.
Code: U5-31
Description:
SPF tray lift-down trouble. The lift-down trouble is detected (STLD is not turned OFF within the specified time.)
Causes:
STUD/ STLD trouble
Remedy:
Check the STUD/ STLD and the harness and the connector. Check the lift-up related circuit (DSPFcnt, DSPF-Driver). Check the lift-up unit.
Code: U6-09
Description:
Side LCC lift motor trouble. • The encoder input value is not changed in 0.13sec (first time) / 0.5sec (2nd or later) after rotation of the motor • The motor is rotated for 18sec or more • The encoder is changed after a certain time of stopping the motor (2 sec, 10 count or more)
Causes:
Sensor trouble. LCC control PWB trouble. Gear breakage. Lift motor trouble.
Remedy:
Use Sim. 4-2 and 4-3 to check the operations of the sensor and the lift motor. Use Sim. 15 to cancel the trouble.
Code: U6-20
Description:
LCC communication trouble. Communication error with the LCC. Communication line test error after turning on the power or canceling the exclusive simulation. The model code discrepancy with the machine model.
Causes:
Connection trouble or disconnection of the connector and the harness. LCC control PWB trouble. Control PWB (PCU) trouble. Malfunction due to noises.
Remedy:
Turn OFF / ON the power to cancel the trouble. Check the connector and the harness in the communication line.
Code: U6-21
Description:
LCC transport motor trouble. • The encoder input value is not changed in 0.06sec after turning on the motor. • The encoder input is changed in a certain time after turning off the motor. (The count reaches 100 when counting for 0.1sec after 5 sec.)
Causes:
Motor lock, motor rpm abnormality, an overcurrent to the motor. LCC control PWB trouble.
Remedy:
Use Sim. 4-3 to check the operation of the transport motor.

Code: U6-22
Description:
LCC 24V power abnormality. DC 24V is not supplied to the LCC
Causes:
Connection trouble or disconnection of the connector and the harness. LCC control PWB trouble. Power source unit trouble.
Remedy:
Check the connector and the harness in the power source line. Check that the power unit and the LCC control PWB is of 24V.
Code: U6-23
Description:
A3LCC tray lock detection trouble (Reverse winding). The LCC tray wire is wound in reverse
Causes:
Reverse winding SW-ON. The wire is wound in reverse. Reverse winding detection SW trouble. Connection trouble of the connector and the harness. LCC control PWB trouble.
Remedy:
Check the wire. Replace the reverse winding SW and the LCC control PWB. Check connection of the connector and the harness.
Code: U6-24
Description:
A3LCC tray lock detection trouble. The LCC tray lock function does not operate normally
Causes:
Tray lock mechanism trouble. Tray lock sensor trouble. Connection trouble of the connector and the harness. LCC control PWB trouble.
Remedy:
Check the tray lock mechanism. Replace the tray lock sensor and the LCC control PWB. Check connection of the connector and the harness.
Code: U6-28
Description:
LCT1 paper feed position abnormality. When the lift-up operation is started, the upper limit sensor is turned OFF before the pick-up SOL is turned ON. (Normally the upper limit sensor is turned OFF only after turning ON the pick-up SOL.)
Causes:
Sensor abnormality, connector and harness connection trouble, PWB trouble. The pick-up roller is kept in the lower position mechanically.
Remedy:
Use Sim. 4-2 and Sim. 4-3 to check the operation of the upper limit sensor and the lift-up operation, and check the wiring.
Code: U6-29
Description:
LCT1 lift-up trouble. When lifting up, the upper limit is not detected within the specified time (A4 LCC: 10 sec, A3 LCC: 8 sec)
Causes:
Upper limit sensor abnormality, tray lift-up motor lock, connector/harness connection trouble, PWB trouble
Remedy:
Use Sim. 4-2 and Sim. 4-3 to check the operation of the upper limit sensor and the lift-up operation, and check the wiring. After making the countermeasure for the trouble section, use Sim. 15 to cancel the trouble.
Code: U6-33
Description:
LCT2 lift-down trouble. The lower limit position (full state) of the LCT2 tray is not detected within the specified time (A4: 10sec, A3: 8sec) from starting lowering.
Causes:
Remaining quantity sensor abnormality, LCT2 tray lift-up motor lock, connector/harness connection trouble, PWB trouble.
Remedy:
Use Sim. 4-2 and Sim. 4-3 to check the operation of the remaining quantity sensor and the LCT2 tray lift-up motor, and check the wiring.
Code: U6-38
Description:
LCT2 paper feed position abnormality. When the lift-up operation is started, the upper limit sensor is turned OFF before the pick-up SOL is turned ON. (Normally the upper limit sensor is turned OFF only after turning ON the pick-up SOL.)
Causes:
Sensor abnormality, connector and harness connection trouble, PWB trouble. The pick-up roller is kept in the lower position mechanically.
Remedy:
Use Sim. 4-2 and Sim. 4-3 to check the operation of the upper limit sensor and the lift-up operation, and check the wiring.
Code: U6-39
Description:
LCT2 lift-up trouble. When lifting up, the upper limit is not detected within the specified time (A4 LCC: 10 sec, A3 LCC: 8 sec)
Causes:
Upper limit sensor abnormality, tray lift-up motor lock, connector/harness connection trouble, PWB trouble.
Remedy:
Use Sim. 4-2 and Sim. 4-3 to check the operation of the upper limit sensor and the lift-up operation, and check the wiring. After making the countermeasure for the trouble section, use Sim. 15 to cancel the trouble.

Code: U6-43
Description:
LCT3 lift-down trouble. The lower limit position (full state) of the LCT3 tray is not detected within the specified time (A4: 10sec, A3: 8sec) from starting lowering
Causes:
Remaining quantity sensor abnormality, LCT3 tray liftup motor lock, connector / harness connection trouble, PWB trouble.
Remedy:
Use Sim. 4-2 and Sim. 4-3 to check the operation of the remaining quantity sensor and the LCT3 tray lift-up motor, and check the wiring.
Code: U6-48
Description:
LCT3 paper feed position abnormality. When the lift-up operation is started, the upper limit sensor is turned OFF before the pick-up SOL is turned ON. (Normally the upper limit sensor is turned OFF only after turning ON the pick-up SOL.)
Causes:
Sensor abnormality, connector and harness connection trouble, PWB trouble. The pick-up roller is kept in the lower position mechanically.
Remedy:
Use Sim. 4-2 and Sim. 4-3 to check the operation of the upper limit sensor and the lift-up operation, and check the wiring.
Code: U6-49
Description:
LCT3 lift-up trouble. When lifting up, the upper limit is not detected within the specified time (A4 LCC: 10 sec, A3 LCC: 8 sec)
Causes:
Upper limit sensor abnormality, tray lift-up motor lock, connector/harness connection trouble, PWB trouble.
Remedy:
Use Sim. 4-2 and Sim. 4-3 to check the operation of the upper limit sensor and the lift-up operation, and check the wiring. After making the countermeasure for the trouble section, use Sim. 15 to cancel the trouble.
Code: U6-51
Description:
LCC incompatible trouble. Error of model code mismatch between the LCC and the main unit
Causes:
Mismatch between the LCC and the main unit
Remedy:
Check the combination of the LCC and the main unit. When connecting to the main unit, the LCC firmware must be changed to the firmware corresponding to the machine.
Code: U6-63
Description:
Manual feed tray lift-down trouble. The lower limit position is not detected within the specified time (10 sec) from starting the lowering operation of the manual feed tray
Causes:
Lower position sensor abnormality, manual tray lift-up motor lock, connector/harness connection trouble, PWB trouble.
Remedy:
Use Sim. 4-2 and Sim. 4-3 to check the operation of the lower limit sensor, and the manual feed tray lift-up motor, and check the wiring. After making the countermeasure for the trouble section, use Sim. 15 to cancel the trouble.
Code: U6-68
Description:
Manual feed tray paper feed position abnormality. When the lift-up operation is started, the upper limit sensor is turned OFF before the pick-up SOL is turned ON. (Normally the upper limit sensor is turned OFF only after turning ON the pick-up SOL.)
Causes:
Sensor abnormality, connector and harness connection trouble, PWB trouble. The pick-up roller is kept in the lower position mechanically.
Remedy:
Use Sim. 4-2 and Sim. 4-3 to check the operation of the upper limit sensor and the lift-up operation, and check the wiring.
Code: U6-69
Description:
Manual feed tray lift-up trouble. When lifting up, the upper limit is not detected within the specified time (10 sec)
Causes:
Upper limit sensor abnormality, tray lift-up motor lock, connector/harness connection trouble, PWB trouble.
Remedy:
Use Sim. 4-2 and Sim. 4-3 to check the operation of the upper limit sensor and the lift-up operation, and check the wiring. After making the countermeasure for the trouble section, use Sim. 15 to cancel the trouble.
Code: U7-50
Description:
Serial vendor communication trouble. Communication error between the ICU and the serial vendor Section ICU
Causes:
Cable disconnection or breakage.
Remedy:
Check connection between the ICU and the serial vendor, and turn OFF /ON the power of the machine and the vendor.

Code: U7-51
Description:
Serial vendor operation trouble. Serial vendor breakdown
Causes:
Serial vendor breakdown3
Remedy:
"Err.XX" (XX: Section code) is displayed on the vendor operation panel. The error generating condition and the cancel method differ depending on the detail code. Refer to the operation manual of the vendor.
Code: U9-00
Description:
Communication trouble between the controller and the operation. Communication establishment error / Framing / Parity / Protocol error
Causes:
Slave unit PWB connector connection trouble. Harness trouble between the slave unit PWB and the ICU PWB. Connector pin breakage of the mother board of the slave unit PWB.
Remedy:
Check connection of the connector and the harness between the slave unit PWB and the ICU PWB. Check the earth wire of the machine.
Code: UC-02
Description:
CPT-ASIC abnormality. Access error to the CPT-ASIC (The ASIC does not operate normally)
Causes:
B to B connector connection abnormality. SCU PWB abnormality. CPT-ASIC abnormality.
Remedy:
Check the B to B connector. Replace the SCU PWB, or replace the option PWB.
Code: UC-12
Description:
CPT-ASIC abnormality (DSPF detection)
Causes:
B to B connector connection abnormality. DSPF PWB abnormality. CPT-ASIC abnormality
Remedy:
Check the B to B connector. Replace the DSPF PWB, or replace the option PWB.
Code: UC-20
Description:
Anti copy module trouble. Communication error between the SCU and the DOCC. Communication test error when turning on the power or after canceling the exclusive simulation.
Causes:
Contact trouble or disconnection of the connector and the harness. Control PWB (SCU) trouble or DOCC PWB trouble. Malfunction due to noises.
Remedy:
Turn OFF /ON the power to cancel. Check the connector and the harness of the communication line. Replace the SCU PWB or replace the DOCC PWB.
Code: UC-21
Description:
The DOCC (Document control) PWB is not detected
Causes:
The DOCC (Document control) PWB is not installed in the DSK model. Connection detection signal trouble.
Remedy:
Check the connection detection signal of the DOCC (Document control) PWB, or replace the PWB.
Code: UC-22
Description:
CPT PWB is not detected. The CPT PWB is not detected under the color kit enable state
Causes:
The CPT PWB is not installed under the color kit enable state, or the connection detection signal trouble.
Remedy:
Check the connection detection signal of the CPT PWB, or replace the PWB.
Code: UC-30
Description:
Anti copy module trouble (DSPF detection)
Causes:
B to B connector connection abnormality. DSPF PWB abnormality, DOCC-ASIC abnormality.
Remedy:
Check the B to B connector. Replace the DSPF PWB, or replace the option PWB.

Code: UC-31
Description:
The DOCC (Document control) PWB is not detected. (DPSF PWB side). DOCC (document control) PWB cannot be detected in the DSK model
Causes:
DOCC (document control) PWB is not installed in the DSK model, or the connection detection signal trouble.
Remedy:
Check the connection detection signal of the DOCC (document control) PWB, or replace the PWB.
Code: UC-32
Description:
The CPT PWB is not detected. (DSPF PWB side). The CPT PWB is not detected under the color kit enable state
Causes:
The CPT PWB is not installed under the color kit enable state, or the connection detection signal trouble.
Remedy:
Check the connection detection signal of the CPT PWB, or replace the PWB.


熱門關(guān)注
· sharp mxm1100常見故障代碼描述,英文手冊3

· sharp mxm1100常見故障代碼描述,英文手冊2

· sharp mxm1100常見故障代碼描述,英文手冊1

· sharp mxm1204常見故障代碼描述,英文手冊5

· sharp mxm1204常見故障代碼描述,英文手冊4

· sharp mxm1204常見故障代碼描述,英文手冊3

· sharp mxm1204常見故障代碼描述,英文手冊2

· sharp mxm1204常見故障代碼描述,英文手冊1

· sharp mxm1205常見故障代碼描述,英文手冊5

· sharp mxm1205常見故障代碼描述,英文手冊4

· sharp mxm1205常見故障代碼描述,英文手冊3

· sharp mxm1205常見故障代碼描述,英文手冊2

· sharp mxm1205常見故障代碼描述,英文手冊1

· sharp mxm160常見故障代碼描述,英文手冊

· sharp mxm182常見故障代碼描述,英文手冊

· sharp mxm200d常見故障代碼描述,英文手冊

· sharp mxm202d常見故障代碼描述,英文手冊

· sharp mxm232d常見故障代碼描述,英文手冊

· sharp mxm260n常見故障代碼描述,英文手冊1

· sharp mxm260n常見故障代碼描述,英文手冊2

· sharp mxm264n常見故障代碼描述,英文手冊2

· sharp mxm264n常見故障代碼描述,英文手冊1

· sharp mxm265n常見故障代碼描述,英文手冊1

· sharp mxm265n常見故障代碼描述,英文手冊2

· sharp mxm266n常見故障代碼描述,英文手冊2

· sharp mxm266n常見故障代碼描述,英文手冊1

· sharp mxm282n常見故障代碼描述,英文手冊2

· sharp mxm282n常見故障代碼描述,英文手冊1

· sharp mxm283n常見故障代碼描述,英文手冊1

· sharp mxm283n常見故障代碼描述,英文手冊2

推薦文章
· toshiba打印機(jī)3040c請求維修ce40什么意思

· toshiba復(fù)印機(jī)錯誤代碼2e66什么意思

· sharpdx-2008uc錯誤代碼f2-40是什么意思

· sharpm2608n無法連接設(shè)備請查看設(shè)備是否處于掃描模式

· 施樂掃描錯誤異常結(jié)束(018-543)sharednameerrorinserver

· sharpar2348n顯示錯誤

· sharpar2348n常見問題報錯解決方法帶圖文

· sharpar2048s問題大全

· shngc-1202-00下載

· sharp1808s掃描儀顯示u-2

· sharp2048n呼叫維修

· sharp2348n恢復(fù)出廠

· sharp打印機(jī)出現(xiàn)錯誤代碼h5-1是設(shè)么意思

· sharp打印復(fù)印一體機(jī)上面顯示有個人的形狀然后紅燈了是什么意思

· 東芝(toshiba)a4多功能一體機(jī)e-studio300d加粉流程圖

· sharp2618nc發(fā)生錯誤。代碼:l4-43

· sharpar2048打印機(jī)顯示需要用戶干預(yù)打印不成怎么辦

· toshiba2303卡紙?jiān)跞コ?/p>

· 東芝toshiba2303a打印機(jī)提示簡易設(shè)置調(diào)整錯誤請按確定鍵重試

· sharp-mx2018uc 報l14-04代碼,那位大師指點(diǎn)一下

· toshiba2303a復(fù)印機(jī)出現(xiàn)e140代碼是什么意思

· sharp ar2008d打印清楚。復(fù)印很淡,手動清楚,調(diào)整方法

· sharp1808s掃描出現(xiàn)u-2

· toshibastudio2303a換碳粉

· sharp mxm700u常見故障代碼描述,英文手冊2

· sharp mxm654fn常見故障代碼描述,英文手冊1

· sharp mxm654fn常見故障代碼描述,英文手冊2

· sharp mxm654fn常見故障代碼描述,英文手冊3

· sharp mxm623u常見故障代碼描述,英文手冊1

· sharp mxm623u常見故障代碼描述,英文手冊2

· sharp mxm620u常見故障代碼描述,英文手冊01

· sharp mxm620u常見故障代碼描述,英文手冊02

· sharp mxm564n常見故障代碼描述,英文手冊01

· sharp mxm564n常見故障代碼描述,英文手冊02

· sharp mxm550u常見故障代碼描述,英文手冊01

· sharp mxm550u常見故障代碼描述,英文手冊02

· sharp mxm503n常見故障代碼描述,英文手冊1

· sharp mxm503n常見故障代碼描述,英文手冊2

· sharp mxm502n常見故障代碼描述,英文手冊2

· sharp mxm502n常見故障代碼描述,英文手冊1

· sharp mxm465n常見故障代碼描述,英文手冊2

· sharp mxm465n常見故障代碼描述,英文手冊1

· sharp mxm464n常見故障代碼描述,英文手冊1

· sharp mxm464n常見故障代碼描述,英文手冊2

· sharp mxm453n常見故障代碼描述,英文手冊1

· sharp mxm453n常見故障代碼描述,英文手冊2

· sharp mxm452n常見故障代碼描述,英文手冊2

· sharp mxm452n常見故障代碼描述,英文手冊1

· sharp mxm450n常見故障代碼描述,英文手冊1

· sharp mxm450n常見故障代碼描述,英文手冊2