Code SC362-02
Description
TD sensor output error: Lower limit (C) TD sensor output: Vt (SP3-210-001 - 004) < output lower limit error threshold (SP3-211-004) is continuously below the lower limit occurrence threshold value (SP3-211-005)
Causes
TD sensor connector missing/dropout
Remedy
1. TD sensor connector missing check
2. Check whether there is any error in the TD sensor harness (disconnection, etc.)
3. If the sensor is defective, replace the development unit.
理光2014ad維修呼叫sc362-01
手機用戶58.218.*.* 發(fā)表于 2022-11-23 理光2014維修呼叫-SC362-01
技術 蔣諾阝 發(fā)表于 2022-11-23 換包載體就好了
Code SC362-02
Description
TD sensor output error: Lower limit (C) TD sensor output: Vt (SP3-210-001 - 004) < output lower limit error threshold (SP3-211-004) is continuously below the lower limit occurrence threshold value (SP3-211-005)
Causes
TD sensor connector missing/dropout
Remedy
1. TD sensor connector missing check
2. Check whether there is any error in the TD sensor harness (disconnection, etc.)
3. If the sensor is defective, replace the development unit.