理光SPC360DNW開機報錯SC572-03,還會出現(xiàn)sc491-02
更新時間:2024/11/23 9:37:13,view:147理光打印機蘇州理光打印機售后服務中心客服熱線69616769,蘇州理光售后電話,理光售后網(wǎng)點,
理光SPC360DNW 開機報錯SC572-03,還會出現(xiàn)sc491-02 兩臺配件互換 還是同樣報錯 請問大師傅 這個機器 如何進維修模式清零
維修手冊,故障代碼,技術通報
理光spc360dnw不通電 姜瘕物 2020-12-23 572-02定影器故障
Code: 572-02
Description: Pressure roller thermistor warm-up error: Center
The center temperature of the pressure roller measured by the thermistor does not reach 20°C within 100 seconds after the heater turns on.
Causes: • Dirty thermopile lenses • Defective thermistor
Remedy: 1. Clean the thermopile lenses. 2. Replace the thermistor at the end of the pressure roller.
維修手冊,故障代碼,技術通報
· 理光如何進維修模式請傅指導
· SC 491
Drum/dev bias error - replace paper transfer unit
Drum/dev bias error - replace high voltage supply unit
Drum/dev bias error - replace drum unit(s)
· sc572-02 壓輥熱敏電阻預熱錯誤: 蘇州理光打印機維修站電話696l6769,企業(yè)一站式服務,維修,耗材配送
理光spc360dnw打印臟 理光打印機 機器序列號W492L400088 2020-12-23
理光spc360dnw不通電 姜瘕物 2020-12-23 572-02定影器故障
Code: 572-02
Description: Pressure roller thermistor warm-up error: Center
The center temperature of the pressure roller measured by the thermistor does not reach 20°C within 100 seconds after the heater turns on.
Causes: • Dirty thermopile lenses • Defective thermistor
Remedy: 1. Clean the thermopile lenses. 2. Replace the thermistor at the end of the pressure roller.