佳能9100報(bào)錯(cuò)代碼E078-0001
更新時(shí)間:2025/2/27 5:47:28,view:132佳能打印機(jī)9100蘇州佳能打印機(jī)售后服務(wù)中心客服熱線69616769,蘇州佳能售后電話,佳能售后網(wǎng)點(diǎn), 佳能9100未注冊(cè)色彩校正, 佳能9100沒有itb單元, 佳能9100激光打印機(jī)錯(cuò)誤代碼e078, canonlbp9100打印機(jī)提示未注冊(cè)色彩校正錯(cuò)誤, 佳能9100cdn維修手冊(cè),維修視頻
維修手冊(cè),故障代碼,技術(shù)通報(bào)
·Code: E078-0001
Description: Primary transfer disengagement mechanism failure
Causes: Primary transfer disengagement mechanism failure At the time of searching the home position: Considering that the coupling of primary transfer engagement/ disengagement drive may not be connected, the solenoid was pulled for maximum 6 times in the condition where the flag was detected once. But the hp sensor did not detect the color print engagement position. * If a flag is not detected even once, it is considered that the ITB unit is absent. At the time of changing the position The position after turning ON/OFF of the solenoid did not match the hp sensor value.
Remedy: Check whether the ITB unit is installed or not. Reconnect the connector J181 on the DC controller PCB. Check the primary transfer roller disengagement switch in the sensor monitor mode. If a failure is found, replace the primary transfer roller disengagement switch assembly. Execute the primary transfer roller engagement/disengagement drive test in the actuator drive mode. If the primary transfer roller does not perform engagement/disengagement, replace the fixing drive unit.
蘇州佳能打印機(jī)維修站電話696l6769,企業(yè)一站式服務(wù),上門維修,耗材配送