理光2004Cdn打印兩張之后直接報代碼SC362-01,是啥問題
更新時間:2024/11/20 23:01:45,view:741理光打印機(jī)2004Cdn蘇州理光打印機(jī)售后服務(wù)中心客服熱線69616769,蘇州理光售后電話,理光售后網(wǎng)點,維修視頻
理光2004Cdn打印兩張之后直接報代碼SC362-01,是啥問題維修手冊,故障代碼,技術(shù)通報 ·36201是黑色的載體Code SC362-01
DescriptionTD sensor output error: Lower limit (C) TD sensor output: Vt (SP3-210-001 - 004) < output lower limit error threshold (SP3-211-004) is continuously below the lower limit occurrence threshold value (SP3-211-005)
CausesTD sensor connector missing/dropout
Remedy1. TD sensor connector missing check
2. Check whether there is any error in the TD sensor harness (disconnection, etc.)
3. If the sensor is defective, replace the development unit. 蘇州理光2004Cdn售后維修電話696l6769,企業(yè)一站式服務(wù),上門維修,耗材配送
DescriptionTD sensor output error: Lower limit (C) TD sensor output: Vt (SP3-210-001 - 004) < output lower limit error threshold (SP3-211-004) is continuously below the lower limit occurrence threshold value (SP3-211-005)
CausesTD sensor connector missing/dropout
Remedy1. TD sensor connector missing check
2. Check whether there is any error in the TD sensor harness (disconnection, etc.)
3. If the sensor is defective, replace the development unit. 蘇州理光2004Cdn售后維修電話696l6769,企業(yè)一站式服務(wù),上門維修,耗材配送