東芝2303AM換過載體初始化完后,重新開機后報C414
更新時間:2024/11/16 23:30:41,view:375東芝打印機2303AM蘇州東芝打印機售后服務(wù)中心客服熱線69616769,蘇州東芝售后電話,東芝售后網(wǎng)點,
東芝2303AM換過載體初始化完后,重新開機后報C414,不能工作
維修手冊,故障代碼,技術(shù)通報 技術(shù) 仁和數(shù)碼 發(fā)表于 2022/8/13 C414], perform the following:
1. Turn ON the power while [0] , [8] are pressed simultaneously.
2. Key in "2002", then press [START].
3. Change the current status counter value "1" , "2" to "0", then press [OK] (to cancel [C413 / C414]).
4. Turn the power OFF , then back ON. Make sure that the equipment enters the normal ready state.
維修手冊,故障代碼,技術(shù)通報
·C414定影器故障,跟換載體沒關(guān)系
·Code C414
Description Fuser unit related service call. Thermistor abnormality during warming up or in ready status after abnormality judgment.
Causes MAIN board Thermistors Heater lamp
蘇州東芝2303AM售后維修電話696l6769,企業(yè)一站式服務(wù),上門維修,耗材配送
1. Turn ON the power while [0] , [8] are pressed simultaneously.
2. Key in "2002", then press [START].
3. Change the current status counter value "1" , "2" to "0", then press [OK] (to cancel [C413 / C414]).
4. Turn the power OFF , then back ON. Make sure that the equipment enters the normal ready state.
熱門圖文